Safety and Accuracy of Percutaneous Image-Guided Core Biopsy of the Spleen

The purpose of this study is to assess the complication rate and diagnostic accuracy of percutaneous image-guided core needle biopsy (CNB) of the spleen at a single center over the course of 12 years. A retrospective review of an institutionally maintained biopsy database was used to identify CNBs o...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of roentgenology (1976) Vol. 206; no. 3; pp. 655 - 659
Main Authors Olson, Michael C, Atwell, Thomas D, Harmsen, William Scott, Konrad, Aaron, King, Rebecca L, Lin, Yi, Wall, Darci J
Format Journal Article
LanguageEnglish
Published United States 01.03.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The purpose of this study is to assess the complication rate and diagnostic accuracy of percutaneous image-guided core needle biopsy (CNB) of the spleen at a single center over the course of 12 years. A retrospective review of an institutionally maintained biopsy database was used to identify CNBs of the spleen performed between October 2002 and January 2015. Clinical notes were reviewed from the date of biopsy to 3 months after biopsy to ascertain whether any immediate or delayed complications had occurred. Minor complications included pain requiring analgesia and incidental asymptomatic bleeding. Major complications were those scored at or above grade 3 according to the National Institutes of Health's Common Terminology Criteria for Adverse Events, version 4.0. The pathology reports issued for each specimen were evaluated and compared with results obtained from splenectomy, biopsy performed at another anatomic site, or longitudinal clinical or imaging follow-up. Sensitivity, specificity, and accuracy were calculated. A total of 97 CNBs of the spleen were performed, 23 of which were CT guided and 74 of which were ultrasound guided. There were seven (7.2%) minor complications and a single (1.0%) major complication; the overall complication rate was 8.2% (n = 8). The diagnostic yield-defined as adequate tissue to establish a diagnosis-of CNB was 93.8%, the sensitivity was 90.7%, the specificity was 100%, and the accuracy was 94.5%. Percutaneous image-guided CNB of the spleen is safe and effective in achieving a tissue diagnosis.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0361-803X
1546-3141
DOI:10.2214/ajr.15.15125