ImageJ-FIJI-Assisted Estimation of Intestinal Layers' Volume: Study in Jejunum-Ileum of Rats
Abstract Background: Studies in the digestive tract often required precision quantification of intestinal volume to observe the effect of certain intervention/condition. Application of stereological methods could bring unbiased and accurate results but commercially computer-assisted systems are not...
Saved in:
Published in | The journal of microscopy & ultrastructure Vol. 12; no. 4; pp. 171 - 176 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
India
Wolters Kluwer - Medknow
01.10.2024
Medknow Publications and Media Pvt. Ltd |
Edition | 2 |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Abstract
Background:
Studies in the digestive tract often required precision quantification of intestinal volume to observe the effect of certain intervention/condition. Application of stereological methods could bring unbiased and accurate results but commercially computer-assisted systems are not widely available. ImageJ-FIJI is an open source software, which could become an alternative choice in the stereological measurement process.
Aim:
This study describes simple stereological quantification methods during volume estimation of jejunum-ileum intestinal layers of the rats using a light microscope and ImageJ-FIJI stereological tool.
Material and Methods:
Six 3-months old male Sprague-Dawley rats were terminated and jejunum-ileum was harvested after perfusion. After removal of intestinal luminal content, whole jejunum-ileum weight was measured. The organ was sampled as 6-10 slabs of 1 cm length in a systematic uniformed random sampling manner. Slabs were cut longitudinally at random angles before flattened and put on filter papers for subsequent tissue processing into 2-3 paraffin blocks. One section of 3 μm thick was sampled from each block, stained using toluidine blue and documented using a light microscope connected to a microstepper apparatus. The volume of the intestinal layers was estimated using a point-counting grid on Image J-FIJI software.
Result:
We compared two sets of counting methods i.e. minimal counting (MC) and rigorous counting (RC) approaches that differ in their respective a/p value. Quantification using RC approach resulted in significantly higher estimated volume of tunica submucosa and tunica muscularis while having more preferable stereological accuracy parameters (CE<5% & CV<10%).
Conclusion:
Although it required longer counting time, rigorous approaches resulted in higher accuracy while still within the range of rule of thumb criteria of 0.2 < CE2/CV2 < 0.5. |
---|---|
Bibliography: | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 2213-879X 2213-8803 2213-8803 |
DOI: | 10.4103/jmau.jmau_53_22 |