Effect of peri‐implant bone resorption on mechanical stress in the implant body: In vivo measured load‐based finite element analysis

Background Research on resolving implant fracture is still gaining attention as it can be a serious treatment failure outcome. The implant fracture is likely to occur due to increased stress in implant body associated with peri‐implant bone resorption. Objective This study aimed to investigate the r...

Full description

Saved in:
Bibliographic Details
Published inJournal of oral rehabilitation Vol. 47; no. 12; pp. 1566 - 1573
Main Authors Bing, Liu, Mito, Takehiko, Yoda, Nobuhiro, Sato, Emika, Shigemitsu, Ryuji, Han, Jian‐Min, Sasaki, Keiichi
Format Journal Article
LanguageEnglish
Published Chichester Wiley Subscription Services, Inc 01.12.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background Research on resolving implant fracture is still gaining attention as it can be a serious treatment failure outcome. The implant fracture is likely to occur due to increased stress in implant body associated with peri‐implant bone resorption. Objective This study aimed to investigate the relationship between degree of peri‐implant bone resorption and stress distribution in implant body by using finite element analysis (FEA). Methods The magnitude and direction of loads on implants at the mandibular molar region were measured with 3D piezoelectric force transducers in a patient during maximal voluntary clenching, grinding and tapping to obtain input for the FEA as the loading condition. Simplified finite element bone models were generated to simulate the six patterns of peri‐implant bone resorption progression which the bone levels from implant platform were set at 0, 1, 2, 3, 4 and 5 mm. Three types of implants with different diameters (3.5, 4.0 and 5.0 mm), corresponding abutments and screws were created. FEA using the in vivo measured load was conducted to investigate how peri‐implant bone loss affects stress distribution in the implant body. Results Loading condition affected stress distribution in the implant body. As bone resorption increased, von Mises stress in the implant body became larger, which was marked in smaller diameter implants, and this change was amply demonstrated when the bone resorption increased from 0 to 2 mm. Conclusion The FEA demonstrated that as peri‐implant bone loss increased, the magnitude of stress in the implant increased, especially in small diameter implants.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0305-182X
1365-2842