Oxidative grafting vs. monolayers self-assembling on gold surface for the preparation of electrochemical immunosensors. Application to the determination of peptide YY

A comparison of the performance of two electrochemical immunosensors for the determination of the anorexigen biomarker peptide YY (PYY) is reported by using as scaffolds screen printed gold electrodes modified either by oxidative grafting of p-aminobenzoic acid (p-ABA) or by assembling of a 4-mercap...

Full description

Saved in:
Bibliographic Details
Published inTalanta (Oxford) Vol. 193; pp. 139 - 145
Main Authors Guerrero, S., Agüí, L., Yáñez-Sedeño, P., Pingarrón, J.M.
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier B.V 01.02.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A comparison of the performance of two electrochemical immunosensors for the determination of the anorexigen biomarker peptide YY (PYY) is reported by using as scaffolds screen printed gold electrodes modified either by oxidative grafting of p-aminobenzoic acid (p-ABA) or by assembling of a 4-mercaptobenzoic acid (4-MBA) SAM. Covalent immobilization of capture antibodies on the surface-confined carboxyl groups was carried out by EDC/NHSS chemistry, and competitive immunoassays between target PYY and Biotin-PYY were implemented. Upon labeling with alkaline phosphatase (AP)-streptavidin conjugate and 1-naphtyl phosphate addition, differential pulse voltammograms recorded between −0.2 and +0.7 V were used as analytical readout. All the steps involved in the functionalization of the electrodes and the preparation of the immunosensors were monitored by electrochemical impedance spectroscopy. The calibration plot for PYY using the AP-Strept-Biotin-PYY(PYY)-anti-PYY-Phe-N-SPAuE immunosensor provided a linear current vs. log [PYY] plot extending between 10−6 and 103 ng/mL PYY with a detection limit of 3 × 10−7 ng/mL. These analytical characteristics are remarkably better than those obtained with the immunosensor prepared with 4-MBA SAM-SPAuEs. The AP-Strept-Biotin-PYY(PYY)-anti-PYY-Phe-N-SPAuE immunosensor was used to analyze human serum and saliva samples spiked with PYY at concentrations fitting with normal levels in these biological fluids. [Display omitted] •Screen-printed gold electrodes modified by oxidative electrografting of aryl-derivatives or by self-assembling of thiol monolayers.•Electrochemical immunosensors using the obesity biomarker peptide YY as the target compound.•Lower limit of detection and wider linear range than other approaches provided by the immunosensor prepared by electrografting.•Application to human serum and saliva.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0039-9140
1873-3573
1873-3573
DOI:10.1016/j.talanta.2018.09.089