Evaluation of the Innovance D-DIMER analytical performance
Background: Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. Methods: We evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Be...
Saved in:
Published in | Clinical chemistry and laboratory medicine Vol. 47; no. 8; pp. 945 - 951 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Berlin
Walter de Gruyter
01.08.2009
De Gruyter |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Abstract | Background: Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. Methods: We evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Behring Coagulation System (BCS) analyzer. Results: Within-run coefficients of variation (CVs) for samples with low, borderline, slightly, and extremely increased D-dimer concentrations were 2.1%–5.5%, whereas between-run CVs for control samples with low and extremely increased D-dimer were 5.5%–8.4%. The assay exhibited good linearity in the working range between 0.17 mg/L and 5.45 mg/L fibrinogen equivalent units (FEU), with the lower limit of detection of 0.099 mg/L FEU. The upper reference value determined in 40 plasma samples from healthy volunteers was 0.495 mg/L FEU. The results obtained in 457 fresh plasma samples were compared with results obtained with VIDAS D-Dimer Exclusion. Passing and Bablok regression analysis demonstrated highly significant correlation (y=1.370x–0.108, r=0.952, p<0.001). Bland and Altman difference plots demonstrated slightly higher results obtained with Innovance D-DIMER that was more pronounced with increasing values. Very good agreement between both assays was observed (κ=0.860; 95% confidence interval (CI), 0.811–0.908). Conclusions: This study demonstrates that Innovance D-DIMER fulfills all analytical requirements for daily routine use. Clin Chem Lab Med 2009;47:945–51. |
---|---|
AbstractList | BACKGROUNDWidespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays.METHODSWe evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Behring Coagulation System (BCS) analyzer.RESULTSWithin-run coefficients of variation (CVs) for samples with low, borderline, slightly, and extremely increased D-dimer concentrations were 2.1%-5.5%, whereas between-run CVs for control samples with low and extremely increased D-dimer were 5.5%-8.4%. The assay exhibited good linearity in the working range between 0.17 mg/L and 5.45 mg/L fibrinogen equivalent units (FEU), with the lower limit of detection of 0.099 mg/L FEU. The upper reference value determined in 40 plasma samples from healthy volunteers was 0.495 mg/L FEU. The results obtained in 457 fresh plasma samples were compared with results obtained with VIDAS D-Dimer Exclusion. Passing and Bablok regression analysis demonstrated highly significant correlation (y=1.370x-0.108, r=0.952, p<0.001). Bland and Altman difference plots demonstrated slightly higher results obtained with Innovance D-DIMER that was more pronounced with increasing values. Very good agreement between both assays was observed (kappa=0.860; 95% confidence interval (CI), 0.811-0.908).CONCLUSIONSThis study demonstrates that Innovance D-DIMER fulfills all analytical requirements for daily routine use. Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. We evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Behring Coagulation System (BCS) analyzer. Within-run coefficients of variation (CVs) for samples with low, borderline, slightly, and extremely increased D-dimer concentrations were 2.1%-5.5%, whereas between-run CVs for control samples with low and extremely increased D-dimer were 5.5%-8.4%. The assay exhibited good linearity in the working range between 0.17 mg/L and 5.45 mg/L fibrinogen equivalent units (FEU), with the lower limit of detection of 0.099 mg/L FEU. The upper reference value determined in 40 plasma samples from healthy volunteers was 0.495 mg/L FEU. The results obtained in 457 fresh plasma samples were compared with results obtained with VIDAS D-Dimer Exclusion. Passing and Bablok regression analysis demonstrated highly significant correlation (y=1.370x-0.108, r=0.952, p<0.001). Bland and Altman difference plots demonstrated slightly higher results obtained with Innovance D-DIMER that was more pronounced with increasing values. Very good agreement between both assays was observed (kappa=0.860; 95% confidence interval (CI), 0.811-0.908). This study demonstrates that Innovance D-DIMER fulfills all analytical requirements for daily routine use. Background: Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. Methods: We evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Behring Coagulation System (BCS) analyzer. Results: Within-run coefficients of variation (CVs) for samples with low, borderline, slightly, and extremely increased D-dimer concentrations were 2.1%–5.5%, whereas between-run CVs for control samples with low and extremely increased D-dimer were 5.5%–8.4%. The assay exhibited good linearity in the working range between 0.17 mg/L and 5.45 mg/L fibrinogen equivalent units (FEU), with the lower limit of detection of 0.099 mg/L FEU. The upper reference value determined in 40 plasma samples from healthy volunteers was 0.495 mg/L FEU. The results obtained in 457 fresh plasma samples were compared with results obtained with VIDAS D-Dimer Exclusion. Passing and Bablok regression analysis demonstrated highly significant correlation (y=1.370x–0.108, r=0.952, p<0.001). Bland and Altman difference plots demonstrated slightly higher results obtained with Innovance D-DIMER that was more pronounced with increasing values. Very good agreement between both assays was observed (κ=0.860; 95% confidence interval (CI), 0.811–0.908). Conclusions: This study demonstrates that Innovance D-DIMER fulfills all analytical requirements for daily routine use. Clin Chem Lab Med 2009;47:945–51. |
Author | Zadro, Renata Coen Herak, Desiree Milos, Marija |
Author_xml | – sequence: 1 givenname: Desiree surname: Coen Herak fullname: Coen Herak, Desiree organization: Clinical Institute of Laboratory Diagnosis, Clinical Hospital Center Zagreb and University School of Medicine, Zagreb, Croatia – sequence: 2 givenname: Marija surname: Milos fullname: Milos, Marija organization: Clinical Institute of Laboratory Diagnosis, Clinical Hospital Center Zagreb and University School of Medicine, Zagreb, Croatia – sequence: 3 givenname: Renata surname: Zadro fullname: Zadro, Renata organization: Clinical Institute of Laboratory Diagnosis, Clinical Hospital Center Zagreb and University School of Medicine, Zagreb, Croatia |
BackLink | http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=21846505$$DView record in Pascal Francis https://www.ncbi.nlm.nih.gov/pubmed/19548843$$D View this record in MEDLINE/PubMed |
BookMark | eNpFkMtPwkAQhzdGIw89ejW96K247269GV6SQAwGuW62yzRWS4u7hch_bysETjPJfJmZ39dBl0VZAEJ3BPeIIOKp35_OehTjuEdJfIHahLMo5IyRy_-eh1JS0kId778wJkLw6Bq1SCy4Upy10fNwZ_KtqbKyCMo0qD4hmBRFuTOFhWAQDiaz4XtgCpPvq8yaPNiAS0u3bsY36Co1uYfbY-2ij9Fw0X8Np2_jSf9lGloWqyokJoksNkZREUtFGKXcErBgBVErYDzCWCiarupfVcKpBJtKI0ElKyZxCjHrosfD3o0rf7bgK73OvIU8NwWUW69lJFhEBavB8ABaV3rvINUbl62N22uCdSNLN7J0I0vXsmr-_rh4m6xhdaaPdmrg4QgYX4dPXR078yeOEsWlwOJ8OPMV_J7mxn3Xz7FI6PmC6_FyLkccL_Wc_QFY-4DJ |
CitedBy_id | crossref_primary_10_1016_j_thromres_2013_12_045 crossref_primary_10_1177_0268355514528131 crossref_primary_10_1016_j_ajem_2020_08_086 crossref_primary_10_1155_2014_519875 crossref_primary_10_1007_s00216_024_05207_x crossref_primary_10_1007_s11239_016_1394_8 crossref_primary_10_1080_00207454_2019_1702546 crossref_primary_10_1159_000449404 crossref_primary_10_1177_2472555219878407 crossref_primary_10_1186_s12872_018_0947_5 crossref_primary_10_1080_10408363_2018_1529734 crossref_primary_10_11613_BM_2020_030705 crossref_primary_10_1093_labmed_lmw001 crossref_primary_10_1111_j_1538_7836_2012_04798_x crossref_primary_10_3390_diagnostics12112770 crossref_primary_10_1016_j_jacc_2019_06_020 crossref_primary_10_1016_j_ajem_2018_07_034 crossref_primary_10_11613_BM_2021_010702 crossref_primary_10_1002_clc_23689 crossref_primary_10_3343_alm_2014_34_1_64 |
Cites_doi | 10.1160/TH08-04-0202 10.1016/j.thromres.2005.08.006 10.1055/s-2000-13217 10.1160/TH06-01-0043 10.1016/S0140-6736(86)90837-8 10.2307/2529310 10.1093/eurheartj/ehn310 10.1093/clinchem/42.3.410 10.1038/clpt.1981.18 10.1055/s-2000-13221 |
ContentType | Journal Article |
Copyright | 2009 INIST-CNRS |
Copyright_xml | – notice: 2009 INIST-CNRS |
DBID | BSCLL IQODW CGR CUY CVF ECM EIF NPM AAYXX CITATION 7X8 |
DOI | 10.1515/CCLM.2009.219 |
DatabaseName | Istex Pascal-Francis Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed CrossRef MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) CrossRef MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine Chemistry |
EISSN | 1437-4331 |
EndPage | 951 |
ExternalDocumentID | 10_1515_CCLM_2009_219 19548843 21846505 ark_67375_QT4_GVQ6F40V_Q |
Genre | Evaluation Studies Journal Article |
GroupedDBID | --- -~0 0R~ 0~D 1CY 29B 354 36B 4.4 53G 5GY 5RE 9-L AAAEU AABBZ AAFNC AAFPC AAGVJ AAILP AALGR AAONY AAOQK AAOTM AAOWA AAPJK AAQCX AASQH AAWFC AAXCG ABAOT ABAQN ABFKT ABFQV ABIQR ABJNI ABLJU ABMIY ABPLS ABRDF ABRQL ABUBZ ABUVI ABVMU ABWLS ABXMZ ABYBW ACEFL ACGFS ACIWK ACMKP ACPMA ACPRK ACXLN ACZBO ADALX ADDWE ADEQT ADGQD ADGYE ADOZN ADUQZ AEDGQ AEGVQ AEICA AEJTT AEKEB AENEX AEQDQ AERZL AEXIE AFAUI AFBAA AFBQV AFCXV AFGDO AFGNR AFQUK AFRAH AFYRI AGBEV AGGNV AHOVO AHVWV AHXUK AIERV AIKXB AJATJ AJHHK AKXKS ALMA_UNASSIGNED_HOLDINGS ALUKF ALYBR AMAVY ASPBG ASYPN AVWKF AZFZN AZMOX BAKPI BBCWN BCIFA BSCLL BWHEM CAG CGQUA COF CS3 DA2 DBYYV DU5 EJD EMOBN F5P FSTRU HZ~ IL9 IY9 KDIRW N9A O9- OBC OBS OEB OES OHH OVD P2P PQQKQ QD8 RDG SA. SLJYH TEORI UK5 WTRAM ~Z8 .55 .GJ AAEMA AAUGY AAZFL ABPTK ACTFP AI. AIGSN DSRVY EBS EYIDJ IQODW ITC VH1 X7M ZA5 CGR CUY CVF ECM EIF NPM AAYXX CITATION 7X8 |
ID | FETCH-LOGICAL-c398t-1ab7c0aa82596813224c1ecec518de34700582fd4348b426ecf6a6e8bd360fe93 |
ISSN | 1434-6621 |
IngestDate | Fri Oct 25 03:51:28 EDT 2024 Thu Sep 12 18:43:47 EDT 2024 Sat Sep 28 07:55:43 EDT 2024 Sun Oct 22 16:07:20 EDT 2023 Wed Oct 30 09:39:23 EDT 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 8 |
Keywords | Performance evaluation Blood coagulation D-dimer particle-enhanced immunoturbidimetric assay D dimer coagulation Assay Medicine Particle evaluation Clinical biology Turbidimetry Performance |
Language | English |
License | CC BY 4.0 |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c398t-1ab7c0aa82596813224c1ecec518de34700582fd4348b426ecf6a6e8bd360fe93 |
Notes | cclm.2009.219.pdf istex:F15DD51A7A003FE8AEEA4D6727C06D978717E7AB ark:/67375/QT4-GVQ6F40V-Q ArticleID:cclm.2009.219 ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
OpenAccessLink | https://edoc.hu-berlin.de/bitstream/18452/13601/1/cclm.2009.219.pdf |
PMID | 19548843 |
PQID | 67537253 |
PQPubID | 23479 |
PageCount | 7 |
ParticipantIDs | proquest_miscellaneous_67537253 crossref_primary_10_1515_CCLM_2009_219 pubmed_primary_19548843 pascalfrancis_primary_21846505 istex_primary_ark_67375_QT4_GVQ6F40V_Q |
PublicationCentury | 2000 |
PublicationDate | 2009-08-01 |
PublicationDateYYYYMMDD | 2009-08-01 |
PublicationDate_xml | – month: 08 year: 2009 text: 2009-08-01 day: 01 |
PublicationDecade | 2000 |
PublicationPlace | Berlin |
PublicationPlace_xml | – name: Berlin – name: Germany |
PublicationTitle | Clinical chemistry and laboratory medicine |
PublicationTitleAlternate | Clin Chem Lab Med |
PublicationYear | 2009 |
Publisher | Walter de Gruyter De Gruyter |
Publisher_xml | – name: Walter de Gruyter – name: De Gruyter |
References | p_2 Passing H (p_5) 1983; 21 p_12 de Moerloose P (p_11) 2008; 100 Bland JM (p_6) 1986; 1 p_8 Dempfle CE. (p_1) 2006; 95 p_10 p_9 Kramer MS (p_7) 1981; 29 Pittet JL (p_4) 1996; 42 |
References_xml | – volume: 21 start-page: 709 year: 1983 ident: p_5 publication-title: Part I. J Clin Chem Clin Biochem contributor: fullname: Passing H – volume: 100 start-page: 505 year: 2008 ident: p_11 publication-title: Thromb Haemost doi: 10.1160/TH08-04-0202 contributor: fullname: de Moerloose P – ident: p_2 doi: 10.1016/j.thromres.2005.08.006 – ident: p_9 doi: 10.1055/s-2000-13217 – volume: 95 start-page: 399 year: 2006 ident: p_1 publication-title: Thromb Haemost doi: 10.1160/TH06-01-0043 contributor: fullname: Dempfle CE. – volume: 1 start-page: 307 year: 1986 ident: p_6 publication-title: Lancet doi: 10.1016/S0140-6736(86)90837-8 contributor: fullname: Bland JM – ident: p_8 doi: 10.2307/2529310 – ident: p_10 doi: 10.1093/eurheartj/ehn310 – volume: 42 start-page: 410 year: 1996 ident: p_4 publication-title: Clin Chem doi: 10.1093/clinchem/42.3.410 contributor: fullname: Pittet JL – volume: 29 start-page: 111 year: 1981 ident: p_7 publication-title: Clin Pharmacol Ther doi: 10.1038/clpt.1981.18 contributor: fullname: Kramer MS – ident: p_12 doi: 10.1055/s-2000-13221 |
SSID | ssj0015547 |
Score | 2.0704355 |
Snippet | Background: Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. Methods: We... Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. We evaluated the... BACKGROUNDWidespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays.METHODSWe... |
SourceID | proquest crossref pubmed pascalfrancis istex |
SourceType | Aggregation Database Index Database Publisher |
StartPage | 945 |
SubjectTerms | Biological and medical sciences coagulation D-dimer evaluation Fibrin Fibrinogen Degradation Products - analysis General aspects Humans Immunoassay Investigative techniques, diagnostic techniques (general aspects) Linear Models Medical sciences Nephelometry and Turbidimetry - methods particle-enhanced immunoturbidimetric assay Reagent Kits, Diagnostic Sensitivity and Specificity |
Title | Evaluation of the Innovance D-DIMER analytical performance |
URI | https://api.istex.fr/ark:/67375/QT4-GVQ6F40V-Q/fulltext.pdf https://www.ncbi.nlm.nih.gov/pubmed/19548843 https://search.proquest.com/docview/67537253 |
Volume | 47 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9MwELaglYALggWW8lhyQNwCTf2KuS3ZdndRu6iorSoukeM4EqyUrtquhPj1zMRO0vIQj0uUpIlVzTeezHg83xDyUkdCK8ZlmA2KPGR5FoUau6YaKWmujGC2KhKbXIizOXu_5Mu60bivLtlmr823X9aV_A-qcA9wxSrZf0C2GRRuwDngC0dAGI5_hfGwoequU_3nVZNTnKwn4ck5ch5oZB1xC9ZXbZHArk-a1MWRpm7-VmUUvHpgDv7HBHyyssiQtdaXzmRtwG62e2ixN4IvA_r8pbH6n3TuSmo-2tLVw7WrDarZ6wYfC2chGZVtmZU3oY4006tKvGMPleOK9J9W5bhlf7LavCK4SJLxxBGI1lZ0jx374kM6mo_H6Wy4nN0k3QEYlrhDusen74aLJm8EzpH0TKow6Ju9Ifc8jy5Ooq-4E1ZvQMKF62Ly-zCjcjdm98hdHycExw70--SGLQ_I7aRG6IDcmnhQHpC3rR4EqyIAPQgaPQi8HgStHgQ7evCQzEfDWXIW-p4YoaEq3oaRzqTpaw2BvRIxLiUwE1ljDY_i3FImsU8kTDtGWZyB92VNIbSwcZZT0S-soo9Ip1yV9jEJmJRGSMHhF8UY8vRzpUXB4UIYqXWPvKrllV456pMUQ0YQbIqCxQ6mKgXBwoOVNJun9PoS9wtKnk5nLD1dTMWI9RfptEeO9sTdvIDrDBAq8B55Ucs_BXFi7kqXdnW9geE4lQNOe-TQwdL-JaQsjBl98sd3n5I7rUo_I53t-to-B5dymx15PfoOWfx3Cw |
link.rule.ids | 315,783,787,27938,27939 |
linkProvider | Walter de Gruyter |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluation+of+the+Innovance+D-DIMER+analytical+performance&rft.jtitle=Clinical+chemistry+and+laboratory+medicine&rft.au=Coen+Herak%2C+Desiree&rft.au=Milos%2C+Marija&rft.au=Zadro%2C+Renata&rft.date=2009-08-01&rft.eissn=1437-4331&rft.volume=47&rft.issue=8&rft.spage=945&rft.epage=951&rft_id=info:doi/10.1515%2FCCLM.2009.219&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1434-6621&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1434-6621&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1434-6621&client=summon |