Evaluation of the Innovance D-DIMER analytical performance

Background: Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. Methods: We evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Be...

Full description

Saved in:
Bibliographic Details
Published inClinical chemistry and laboratory medicine Vol. 47; no. 8; pp. 945 - 951
Main Authors Coen Herak, Desiree, Milos, Marija, Zadro, Renata
Format Journal Article
LanguageEnglish
Published Berlin Walter de Gruyter 01.08.2009
De Gruyter
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background: Widespread use of D-dimer in recent years has led to the development of a number of new fully automated quantitative D-dimer assays. Methods: We evaluated the analytical performance of the particle-enhanced immunoturbidimetric assay Innovance D-DIMER (Siemens Medical Solutions) on the Behring Coagulation System (BCS) analyzer. Results: Within-run coefficients of variation (CVs) for samples with low, borderline, slightly, and extremely increased D-dimer concentrations were 2.1%–5.5%, whereas between-run CVs for control samples with low and extremely increased D-dimer were 5.5%–8.4%. The assay exhibited good linearity in the working range between 0.17 mg/L and 5.45 mg/L fibrinogen equivalent units (FEU), with the lower limit of detection of 0.099 mg/L FEU. The upper reference value determined in 40 plasma samples from healthy volunteers was 0.495 mg/L FEU. The results obtained in 457 fresh plasma samples were compared with results obtained with VIDAS D-Dimer Exclusion. Passing and Bablok regression analysis demonstrated highly significant correlation (y=1.370x–0.108, r=0.952, p<0.001). Bland and Altman difference plots demonstrated slightly higher results obtained with Innovance D-DIMER that was more pronounced with increasing values. Very good agreement between both assays was observed (κ=0.860; 95% confidence interval (CI), 0.811–0.908). Conclusions: This study demonstrates that Innovance D-DIMER fulfills all analytical requirements for daily routine use. Clin Chem Lab Med 2009;47:945–51.
Bibliography:cclm.2009.219.pdf
istex:F15DD51A7A003FE8AEEA4D6727C06D978717E7AB
ark:/67375/QT4-GVQ6F40V-Q
ArticleID:cclm.2009.219
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1434-6621
1437-4331
DOI:10.1515/CCLM.2009.219