Intraocular Pressure Measurement Accuracy and Repeatability of a Modified Goldmann Prism: Multicenter Randomized Clinical Trial

To clinically evaluate a modified surface Goldmann applanation tomometer (GAT) prism for intraocular pressure (IOP) accuracy, repeatability, and safety. Prospective, open-label, randomized, controlled, multicenter reference device reliability and validity analysis. A GAT and a modified surface GAT p...

Full description

Saved in:
Bibliographic Details
Published inAmerican journal of ophthalmology Vol. 196; pp. 145 - 153
Main Authors McCafferty, Sean, Tetrault, Kyle, McColgin, Ann, Chue, Warren, Levine, Jason, Muller, Melissa
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.12.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To clinically evaluate a modified surface Goldmann applanation tomometer (GAT) prism for intraocular pressure (IOP) accuracy, repeatability, and safety. Prospective, open-label, randomized, controlled, multicenter reference device reliability and validity analysis. A GAT and a modified surface GAT prism measured IOP on 173 unique eyes. The study design and analysis complied with FDA 510(k) and ANSIZ80.10-2014 guidelines. All eyes were randomized to IOP measurement by 1 of 5 standard prisms or 5 modified prisms, each from a different manufacturing lot. Pressures were measured by 6 investigators, 2 times with each prism, for a total of 1384 IOP measurements. Analysis included Bland-Altman difference accuracy, intraoperator and interoperator IOP measurement, and manufactured lot repeatability. Bland-Altman indicated no IOP measurements pairs outside the ±5 mm Hg guidelines. Operator and manufactured lot repeatability F tests and 1-way ANOVAs indicated no statistical difference between the standard and modified prisms (all P > .10). The difference in IOP measurements of the standard and modified prisms correlated well to Dresdner central corneal thickness (CCT) correction (P = .01). A modified surface replacement prism is statistically equivalent to a flat-surfaced prism. The modified surface prism indicated statistically significant correction for CCT requiring further testing outside the ANSI standard limits (0.500 mm < CCT < 0.600 mm) to examine its full potential.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Undefined-3
ISSN:0002-9394
1879-1891
1879-1891
DOI:10.1016/j.ajo.2018.08.051