Reliability and accuracy of an automated tracking algorithm to measure controlled passive and active muscle fascicle length changes from ultrasound

Manual tracking of muscle fascicle length changes from ultrasound images is a subjective and time-consuming process. The purpose of this study was to assess the repeatability and accuracy of an automated algorithm for tracking fascicle length changes in the medial gastrocnemius (MG) muscle during pa...

Full description

Saved in:
Bibliographic Details
Published inComputer methods in biomechanics and biomedical engineering Vol. 16; no. 6; pp. 678 - 687
Main Authors Gillett, Jarred G., Barrett, Rod S., Lichtwark, Glen A.
Format Journal Article
LanguageEnglish
Published Abingdon, UK Taylor & Francis 2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Manual tracking of muscle fascicle length changes from ultrasound images is a subjective and time-consuming process. The purpose of this study was to assess the repeatability and accuracy of an automated algorithm for tracking fascicle length changes in the medial gastrocnemius (MG) muscle during passive length changes and active contractions (isometric, concentric and eccentric) performed on a dynamometer. The freely available, automated tracking algorithm was based on the Lucas-Kanade optical flow algorithm with an affine optic flow extension, which accounts for image translation, dilation, rotation and shear between consecutive frames of an image sequence. Automated tracking was performed by three experienced assessors, and within- and between-examiner repeatability was computed using the coefficient of multiple determination (CMD). Fascicle tracking data were also compared with manual digitisation of the same image sequences, and the level of agreement between the two methods was calculated using the coefficient of multiple correlation (CMC). The CMDs across all test conditions ranged from 0.50 to 0.93 and were all above 0.98 when recomputed after the systematic error due to the estimate of the initial fascicle length on the first ultrasound frame was removed from the individual fascicle length waveforms. The automated and manual tracking approaches produced similar fascicle length waveforms, with an overall CMC of 0.88, which improved to 0.94 when the initial length offset was removed. Overall results indicate that the automated fascicle tracking algorithm was a repeatable, accurate and time-efficient method for estimating fascicle length changes of the MG muscle in controlled passive and active conditions.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:1025-5842
1476-8259
DOI:10.1080/10255842.2011.633516