Q-PPG: Energy-Efficient PPG-Based Heart Rate Monitoring on Wearable Devices
Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG s...
Saved in:
Published in | IEEE transactions on biomedical circuits and systems Vol. 15; no. 6; pp. 1196 - 1209 |
---|---|
Main Authors | , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
IEEE
01.12.2021
The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Subjects | |
Online Access | Get full text |
ISSN | 1932-4545 1940-9990 1940-9990 |
DOI | 10.1109/TBCAS.2021.3122017 |
Cover
Loading…
Abstract | Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their better generalization, are considered to be too complex to deploy on wearable devices.
In this work, we tackle these limitations, proposing a design space exploration methodology to automatically generate a rich family of deep Temporal Convolutional Networks (TCNs) for HR monitoring, all derived from a single "seed" model. Our flow involves a cascade of two Neural Architecture Search (NAS) tools and a hardware-friendly quantizer, whose combination yields both highly accurate and extremely lightweight models. When tested on the PPG-Dalia dataset, our most accurate model sets a new state-of-the-art in Mean Absolute Error. Furthermore, we deploy our TCNs on an embedded platform featuring a STM32WB55 microcontroller, demonstrating their suitability for real-time execution. Our most accurate quantized network achieves 4.41 Beats Per Minute (BPM) of Mean Absolute Error (MAE), with an energy consumption of 47.65 mJ and a memory footprint of 412 kB. At the same time, the smallest network that obtains a MAE <inline-formula><tex-math notation="LaTeX">< </tex-math></inline-formula> 8 BPM, among those generated by our flow, has a memory footprint of 1.9 kB and consumes just 1.79 mJ per inference. |
---|---|
AbstractList | Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject’s arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their better generalization, are considered to be too complex to deploy on wearable devices. In this work, we tackle these limitations, proposing a design space exploration methodology to automatically generate a rich family of deep Temporal Convolutional Networks (TCNs) for HR monitoring, all derived from a single “seed” model. Our flow involves a cascade of two Neural Architecture Search (NAS) tools and a hardware-friendly quantizer, whose combination yields both highly accurate and extremely lightweight models. When tested on the PPG-Dalia dataset, our most accurate model sets a new state-of-the-art in Mean Absolute Error. Furthermore, we deploy our TCNs on an embedded platform featuring a STM32WB55 microcontroller, demonstrating their suitability for real-time execution. Our most accurate quantized network achieves 4.41 Beats Per Minute (BPM) of Mean Absolute Error (MAE), with an energy consumption of 47.65 mJ and a memory footprint of 412 kB. At the same time, the smallest network that obtains a MAE [Formula Omitted] 8 BPM, among those generated by our flow, has a memory footprint of 1.9 kB and consumes just 1.79 mJ per inference. Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their better generalization, are considered to be too complex to deploy on wearable devices. In this work, we tackle these limitations, proposing a design space exploration methodology to automatically generate a rich family of deep Temporal Convolutional Networks (TCNs) for HR monitoring, all derived from a single "seed" model. Our flow involves a cascade of two Neural Architecture Search (NAS) tools and a hardware-friendly quantizer, whose combination yields both highly accurate and extremely lightweight models. When tested on the PPG-Dalia dataset, our most accurate model sets a new state-of-the-art in Mean Absolute Error. Furthermore, we deploy our TCNs on an embedded platform featuring a STM32WB55 microcontroller, demonstrating their suitability for real-time execution. Our most accurate quantized network achieves 4.41 Beats Per Minute (BPM) of Mean Absolute Error (MAE), with an energy consumption of 47.65 mJ and a memory footprint of 412 kB. At the same time, the smallest network that obtains a MAE 8 BPM, among those generated by our flow, has a memory footprint of 1.9 kB and consumes just 1.79 mJ per inference. Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their better generalization, are considered to be too complex to deploy on wearable devices. In this work, we tackle these limitations, proposing a design space exploration methodology to automatically generate a rich family of deep Temporal Convolutional Networks (TCNs) for HR monitoring, all derived from a single "seed" model. Our flow involves a cascade of two Neural Architecture Search (NAS) tools and a hardware-friendly quantizer, whose combination yields both highly accurate and extremely lightweight models. When tested on the PPG-Dalia dataset, our most accurate model sets a new state-of-the-art in Mean Absolute Error. Furthermore, we deploy our TCNs on an embedded platform featuring a STM32WB55 microcontroller, demonstrating their suitability for real-time execution. Our most accurate quantized network achieves 4.41 Beats Per Minute (BPM) of Mean Absolute Error (MAE), with an energy consumption of 47.65 mJ and a memory footprint of 412 kB. At the same time, the smallest network that obtains a MAE <inline-formula><tex-math notation="LaTeX">< </tex-math></inline-formula> 8 BPM, among those generated by our flow, has a memory footprint of 1.9 kB and consumes just 1.79 mJ per inference. Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their better generalization, are considered to be too complex to deploy on wearable devices. In this work, we tackle these limitations, proposing a design space exploration methodology to automatically generate a rich family of deep Temporal Convolutional Networks (TCNs) for HR monitoring, all derived from a single "seed" model. Our flow involves a cascade of two Neural Architecture Search (NAS) tools and a hardware-friendly quantizer, whose combination yields both highly accurate and extremely lightweight models. When tested on the PPG-Dalia dataset, our most accurate model sets a new state-of-the-art in Mean Absolute Error. Furthermore, we deploy our TCNs on an embedded platform featuring a STM32WB55 microcontroller, demonstrating their suitability for real-time execution. Our most accurate quantized network achieves 4.41 Beats Per Minute (BPM) of Mean Absolute Error (MAE), with an energy consumption of 47.65 mJ and a memory footprint of 412 kB. At the same time, the smallest network that obtains a MAE 8 BPM, among those generated by our flow, has a memory footprint of 1.9 kB and consumes just 1.79 mJ per inference.Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs) caused by movements of the subject's arm affect the performance of PPG-based HR tracking. This is typically addressed coupling the PPG signal with acceleration measurements from an inertial sensor. Unfortunately, most standard approaches of this kind rely on hand-tuned parameters, which impair their generalization capabilities and their applicability to real data in the field. In contrast, methods based on deep learning, despite their better generalization, are considered to be too complex to deploy on wearable devices. In this work, we tackle these limitations, proposing a design space exploration methodology to automatically generate a rich family of deep Temporal Convolutional Networks (TCNs) for HR monitoring, all derived from a single "seed" model. Our flow involves a cascade of two Neural Architecture Search (NAS) tools and a hardware-friendly quantizer, whose combination yields both highly accurate and extremely lightweight models. When tested on the PPG-Dalia dataset, our most accurate model sets a new state-of-the-art in Mean Absolute Error. Furthermore, we deploy our TCNs on an embedded platform featuring a STM32WB55 microcontroller, demonstrating their suitability for real-time execution. Our most accurate quantized network achieves 4.41 Beats Per Minute (BPM) of Mean Absolute Error (MAE), with an energy consumption of 47.65 mJ and a memory footprint of 412 kB. At the same time, the smallest network that obtains a MAE 8 BPM, among those generated by our flow, has a memory footprint of 1.9 kB and consumes just 1.79 mJ per inference. |
Author | Risso, Matteo Benatti, Simone Benini, Luca Macii, Enrico Burrello, Alessio Pagliari, Daniele Jahier Poncino, Massimo |
Author_xml | – sequence: 1 givenname: Alessio orcidid: 0000-0002-6215-8220 surname: Burrello fullname: Burrello, Alessio email: alessio.burrello@unibo.it organization: Department of Electrical, Electronic, and Information Engineering, University of Bologna, Bologna, Italy – sequence: 2 givenname: Daniele Jahier orcidid: 0000-0002-2872-7071 surname: Pagliari fullname: Pagliari, Daniele Jahier email: daniele.jahier@polito.it organization: Department of Control and Computer Engineering, Politecnico di Torino, Turin, Italy – sequence: 3 givenname: Matteo orcidid: 0000-0002-4641-9742 surname: Risso fullname: Risso, Matteo email: matteo.risso@studenti.polito.it organization: Department of Control and Computer Engineering, Politecnico di Torino, Turin, Italy – sequence: 4 givenname: Simone orcidid: 0000-0002-5700-5342 surname: Benatti fullname: Benatti, Simone email: simone.benatti@unibo.it organization: Department of Electrical, Electronic, and Information Engineering, University of Bologna, Bologna, Italy – sequence: 5 givenname: Enrico orcidid: 0000-0001-9046-5618 surname: Macii fullname: Macii, Enrico email: enrico.macii@polito.it organization: Interuniversity Department of Regional and Urban Studies and Planning, Politecnico di Torino, Turin, Italy – sequence: 6 givenname: Luca orcidid: 0000-0001-8068-3806 surname: Benini fullname: Benini, Luca email: luca.benini@unibo.it organization: Department of Electrical, Electronic, and Information Engineering, University of Bologna, Bologna, Italy – sequence: 7 givenname: Massimo orcidid: 0000-0002-1369-9688 surname: Poncino fullname: Poncino, Massimo email: massimo.poncino@polito.it organization: Department of Control and Computer Engineering, Politecnico di Torino, Turin, Italy |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/34673496$$D View this record in MEDLINE/PubMed |
BookMark | eNp9kUlPHDEQRq0IFLb8gSChlnLh0hNv7bZzg8mwCCKWEOVoudvVyKjHBtuDxL_Hwww5cMjJJfu9Urm-HbThgweEvhI8IQSr73fH06PfE4opmTBCKSbtJ7RNFMe1UgpvLGtGa97wZgvtpPSAcSOoop_RFuOiZVyJbXRxU19fn_6oZh7i_Us9GwbXO_C5Krf1sUlgqzMwMVe3JkP1K3iXQ3T-vgq--lseTDdC9ROeXQ9pD20OZkzwZX3uoj8ns7vpWX15dXo-Pbqse6aaXPcChLRgwEpiCafWCAnCGtt1TU-VNIMkjHRty1thQGCjyg-kbfEArOtgYLvocNX3MYanBaSs5y71MI7GQ1gkTRvJOaOCyIJ--4A-hEX0ZTpNBcNMkZaJQh2sqUU3B6sfo5ub-KLf11QAuQL6GFKKMOjeZZNd8DkaN2qC9TIR_ZaIXiai14kUlX5Q37v_V9pfSQ4A_gmqkUyVsV8BotKUPQ |
CODEN | ITBCCW |
CitedBy_id | crossref_primary_10_1021_acsami_4c22895 crossref_primary_10_1109_JIOT_2023_3263290 crossref_primary_10_1016_j_bspc_2024_106240 crossref_primary_10_1016_j_eswa_2024_123167 crossref_primary_10_1016_j_bspc_2024_106287 crossref_primary_10_1016_j_measurement_2024_116546 crossref_primary_10_1109_JSEN_2024_3378115 crossref_primary_10_1016_j_knosys_2024_112769 crossref_primary_10_1016_j_health_2024_100329 crossref_primary_10_1109_TBCAS_2023_3348844 crossref_primary_10_3390_s23156896 crossref_primary_10_3390_s24185908 crossref_primary_10_1002_itl2_631 crossref_primary_10_3390_app13074351 crossref_primary_10_1109_MDAT_2024_3432862 crossref_primary_10_1002_ett_4932 crossref_primary_10_1109_JIOT_2023_3322947 crossref_primary_10_1109_TBME_2024_3477275 crossref_primary_10_1016_j_iot_2023_101007 |
Cites_doi | 10.1109/JSEN.2021.3073047 10.1109/CVPR.2019.00293 10.1109/CVPR42600.2020.01298 10.1109/JBHI.2020.3022211 10.1007/s40846-019-00468-9 10.1109/EMBC44109.2020.9175346 10.1109/TBME.2017.2676243 10.1016/j.chaos.2015.05.005 10.1109/ICACCAF.2016.7748986 10.3390/s19143079 10.1109/JIOT.2020.3008170 10.1109/LSP.2015.2509868 10.1109/TBCAS.2019.2959160 10.1109/ISCAS51556.2021.9401362 10.1109/TC.2021.3066883 10.3390/electronics3020282 10.1109/ISCAS51556.2021.9401282 10.1109/TBCAS.2020.3001675 10.1109/EMBC44109.2020.9175349 10.1109/TBME.2019.2919137 10.1109/TBCAS.2019.2892297 10.1109/DAC18074.2021.9586187 10.1109/TBME.2015.2406332 10.1155/2018/5853917 10.1109/TBME.2014.2359372 10.1109/CVPR.2018.00171 10.1109/TCSII.2020.2983648 10.23919/EUSIPCO.2017.8081656 10.1109/CVPR42600.2020.00242 10.1109/JBHI.2018.2871177 10.1007/978-3-319-49409-8_7 |
ContentType | Journal Article |
Copyright | Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2021 |
Copyright_xml | – notice: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2021 |
DBID | 97E RIA RIE AAYXX CITATION CGR CUY CVF ECM EIF NPM 7QO 7SP 7TB 8FD FR3 L7M P64 7X8 |
DOI | 10.1109/TBCAS.2021.3122017 |
DatabaseName | IEEE Xplore (IEEE) IEEE All-Society Periodicals Package (ASPP) 1998–Present IEEE Electronic Library (IEL) CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed Biotechnology Research Abstracts Electronics & Communications Abstracts Mechanical & Transportation Engineering Abstracts Technology Research Database Engineering Research Database Advanced Technologies Database with Aerospace Biotechnology and BioEngineering Abstracts MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Biotechnology Research Abstracts Technology Research Database Mechanical & Transportation Engineering Abstracts Electronics & Communications Abstracts Engineering Research Database Advanced Technologies Database with Aerospace Biotechnology and BioEngineering Abstracts MEDLINE - Academic |
DatabaseTitleList | Biotechnology Research Abstracts MEDLINE MEDLINE - Academic |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database – sequence: 3 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Engineering |
EISSN | 1940-9990 |
EndPage | 1209 |
ExternalDocumentID | 34673496 10_1109_TBCAS_2021_3122017 9583926 |
Genre | orig-research Research Support, Non-U.S. Gov't Journal Article |
GrantInformation_xml | – fundername: EU Grant Bonsapp grantid: 101015848 |
GroupedDBID | --- 0R~ 29I 4.4 5GY 5VS 6IK 97E AAJGR AARMG AASAJ AAWTH ABAZT ABQJQ ABVLG ACIWK ACPRK AENEX AETIX AFRAH AGQYO AGSQL AHBIQ AKJIK AKQYR ALMA_UNASSIGNED_HOLDINGS ATWAV BEFXN BFFAM BGNUA BKEBE BPEOZ CS3 DU5 EBS EJD F5P HZ~ IFIPE IPLJI JAVBF LAI M43 O9- OCL P2P RIA RIE RNS AAYXX CITATION RIG CGR CUY CVF ECM EIF NPM 7QO 7SP 7TB 8FD FR3 L7M P64 7X8 |
ID | FETCH-LOGICAL-c395t-c6e68deaed81d142da68e6dadbb5c298af8131b77476ae60a95458d70fe3bbef3 |
IEDL.DBID | RIE |
ISSN | 1932-4545 1940-9990 |
IngestDate | Thu Jul 10 18:35:49 EDT 2025 Mon Jun 30 16:11:40 EDT 2025 Thu Jan 02 22:54:17 EST 2025 Thu Apr 24 23:05:02 EDT 2025 Tue Jul 01 05:12:54 EDT 2025 Wed Aug 27 02:04:21 EDT 2025 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Language | English |
License | https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html https://doi.org/10.15223/policy-029 https://doi.org/10.15223/policy-037 |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c395t-c6e68deaed81d142da68e6dadbb5c298af8131b77476ae60a95458d70fe3bbef3 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ORCID | 0000-0002-2872-7071 0000-0001-9046-5618 0000-0002-1369-9688 0000-0002-5700-5342 0000-0002-4641-9742 0000-0001-8068-3806 0000-0002-6215-8220 |
OpenAccessLink | http://hdl.handle.net/11380/1274657 |
PMID | 34673496 |
PQID | 2630391736 |
PQPubID | 85510 |
PageCount | 14 |
ParticipantIDs | crossref_citationtrail_10_1109_TBCAS_2021_3122017 ieee_primary_9583926 proquest_journals_2630391736 proquest_miscellaneous_2584432618 pubmed_primary_34673496 crossref_primary_10_1109_TBCAS_2021_3122017 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2021-12-01 |
PublicationDateYYYYMMDD | 2021-12-01 |
PublicationDate_xml | – month: 12 year: 2021 text: 2021-12-01 day: 01 |
PublicationDecade | 2020 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States – name: New York |
PublicationTitle | IEEE transactions on biomedical circuits and systems |
PublicationTitleAbbrev | TBCAS |
PublicationTitleAlternate | IEEE Trans Biomed Circuits Syst |
PublicationYear | 2021 |
Publisher | IEEE The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Publisher_xml | – name: IEEE – name: The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
References | ref13 (ref49) 2014 ref12 ref15 ref11 ref10 ref17 ref16 (ref51) 0 ref19 castaneda (ref5) 2018; 4 ref18 zhang (ref28) 2019; 18 ref46 apple (ref2) 0 ref47 ref44 ref43 (ref34) 0 (ref50) 0 ref8 ref7 ref4 ref6 ref40 fitbit (ref3) 0 ref31 ref30 biosignalsplux (ref48) 0 ref1 ref39 ref38 han (ref45) 0 choi (ref35) 2018 salehizadeh (ref14) 2016; 16 integrated (ref33) 0 cai (ref42) 0 ref24 ref23 ref26 lin (ref41) 2020; 33 ref25 ref20 ref22 ref21 ioffe (ref37) 0; 9 ref27 (ref32) 0 neuneier (ref36) 0 bai (ref29) 2018 (ref9) 2020 |
References_xml | – ident: ref25 doi: 10.1109/JSEN.2021.3073047 – year: 0 ident: ref42 article-title: Proxylessnas: Direct neural architecture search on target task and hardware publication-title: Proc Int Conf Learn Representations – ident: ref40 doi: 10.1109/CVPR.2019.00293 – ident: ref43 doi: 10.1109/CVPR42600.2020.01298 – ident: ref27 doi: 10.1109/JBHI.2020.3022211 – year: 0 ident: ref50 – year: 0 ident: ref34 – ident: ref8 doi: 10.1007/s40846-019-00468-9 – ident: ref24 doi: 10.1109/EMBC44109.2020.9175346 – ident: ref11 doi: 10.1109/TBME.2017.2676243 – ident: ref1 doi: 10.1016/j.chaos.2015.05.005 – ident: ref7 doi: 10.1109/ICACCAF.2016.7748986 – year: 0 ident: ref45 article-title: Deep compression: Compressing deep neural networks with pruning, trained quantization and Huffman coding publication-title: Proc Int Conf Learn Representations (ICLR) – year: 0 ident: ref32 – volume: 33 year: 2020 ident: ref41 article-title: McuNet: Tiny deep learning on IoT devices publication-title: Adv Neural Inf Process Syst – year: 0 ident: ref51 – ident: ref10 doi: 10.3390/s19143079 – ident: ref31 doi: 10.1109/JIOT.2020.3008170 – ident: ref22 doi: 10.1109/LSP.2015.2509868 – ident: ref20 doi: 10.1109/TBCAS.2019.2959160 – ident: ref21 doi: 10.1109/ISCAS51556.2021.9401362 – volume: 9 start-page: 448 year: 0 ident: ref37 article-title: Batch normalization: Accelerating deep network training by reducing internal covariate shift publication-title: Proc 32nd Int Conf Mach Learn – volume: 4 start-page: 195?202 year: 2018 ident: ref5 article-title: A review on wearable photoplethysmography sensors and their potential future applications in health care publication-title: J Biosensors Bioelectron – ident: ref46 doi: 10.1109/TC.2021.3066883 – start-page: 373 year: 0 ident: ref36 article-title: How to train neural networks publication-title: Neural Networks Tricks of the Trade – year: 2018 ident: ref29 article-title: An empirical evaluation of generic convolutional and recurrent networks for sequence modeling – ident: ref4 doi: 10.3390/electronics3020282 – ident: ref19 doi: 10.1109/ISCAS51556.2021.9401282 – ident: ref18 doi: 10.1109/TBCAS.2020.3001675 – year: 2018 ident: ref35 article-title: Pact: Parameterized clipping activation for quantized neural networks – volume: 16 start-page: 10?30 year: 2016 ident: ref14 article-title: A novel time-varying spectral filtering algorithm for reconstruction of motion artifact corrupted heart rate signals during intense physical activities using a wearable photoplethysmogram sensor publication-title: SENSORS – ident: ref23 doi: 10.1109/EMBC44109.2020.9175349 – ident: ref26 doi: 10.1109/TBME.2019.2919137 – ident: ref17 doi: 10.1109/TBCAS.2019.2892297 – year: 0 ident: ref2 article-title: Apple watch series – year: 0 ident: ref48 – year: 2014 ident: ref49 – year: 2020 ident: ref9 article-title: Neurosky – ident: ref39 doi: 10.1109/DAC18074.2021.9586187 – ident: ref15 doi: 10.1109/TBME.2015.2406332 – ident: ref16 doi: 10.1155/2018/5853917 – ident: ref6 doi: 10.1109/TBME.2014.2359372 – volume: 18 year: 2019 ident: ref28 article-title: A survey on deep learning based brain computer interface: Recent advances and new frontiers publication-title: J Neural Eng – year: 0 ident: ref33 – ident: ref38 doi: 10.1109/CVPR.2018.00171 – ident: ref44 doi: 10.1109/TCSII.2020.2983648 – ident: ref12 doi: 10.23919/EUSIPCO.2017.8081656 – year: 0 ident: ref3 article-title: Fitbit charge 4 – ident: ref47 doi: 10.1109/CVPR42600.2020.00242 – ident: ref13 doi: 10.1109/JBHI.2018.2871177 – ident: ref30 doi: 10.1007/978-3-319-49409-8_7 |
SSID | ssj0056292 |
Score | 2.4551344 |
Snippet | Hearth Rate (HR) monitoring is increasingly performed in wrist-worn devices using low-cost photoplethysmography (PPG) sensors. However, Motion Artifacts (MAs)... |
SourceID | proquest pubmed crossref ieee |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 1196 |
SubjectTerms | Algorithms Arm Cascade flow Deep learning deep neural networks Embedded systems Energy consumption Energy efficiency Footprints healthcare Heart rate Heart Rate - physiology Hearth rate monitoring Inertial sensing devices Microcontrollers Monitoring Photoplethysmography quantization Sensors Signal Processing, Computer-Assisted Wearable computers Wearable devices Wearable Electronic Devices Wearable technology Wrist |
Title | Q-PPG: Energy-Efficient PPG-Based Heart Rate Monitoring on Wearable Devices |
URI | https://ieeexplore.ieee.org/document/9583926 https://www.ncbi.nlm.nih.gov/pubmed/34673496 https://www.proquest.com/docview/2630391736 https://www.proquest.com/docview/2584432618 |
Volume | 15 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1Lb9QwEB61PZUDfQFd2iIjcQNvkzhxnN7asmUFKirQit4ix55cQNmqzV749Z1xHioVIG5RbCeOPZ75JvZ8A_Am13lircukSY2SJCFaVlkdySSvXV3XxlvFgcLnn_X8Kv14nV2vwLsxFgYRw-EznPJl2Mv3C7fkX2WHRcbmXK_CKjluXazWoHXJjIcEyIxHmMc7GwJkouLw8uT0-Bu5gklMHmpCFo8z7ynSEEyW_ps9CglW_o41g80524DzobfdUZMf02VbTd2vR0SO__s5m_C0B5_iuJOWLVjBZhuePKAk3IFPX-TFxYcjMQsxgXIWGCboMYLuyhMyeV7MaXG04iuBVNFpBG4pFo34TgUciSXeY9A_z-DqbHZ5Opd9wgXpVJG10mnUxqNFTyg2ThNvtUHtra-qzCWFsbWJVVwRYsy1RR3ZgrfdfB7VqKoKa_Uc1ppFg7sgdIQ2R-OUd0XqyQl1pOHTLLfKpwRCcALxMOyl69nIOSnGzzJ4JVFRhlkredbKftYm8HZsc9Nxcfyz9g4P-VizH-0J7A-zW_bL9a5MtGKm_FxR8euxmBYa757YBhdLqkNQLSWwG5sJvOikYnz2IEwv__zOPVjnnnWnYPZhrb1d4gFhmbZ6FYT4Hh_s69s |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1Lb9QwEB71caA9AKWlLBQwEjfwNoljx-mtjy1b2q0KbEVvkWNPLqAsguyFX8_YeYgiqLhFsZ049njmm9jzDcDrTGWJMVZynWrBSUIUL2UV8SSrbFVV2hnhA4Vnl2p6nb6_kTcr8HaIhUHEcPgMx_4y7OW7hV36X2X7ufTmXK3COtl9GbfRWr3eJUMeUiB7ROKZvGUfIhPl-_Oj48NP5AwmMfmoCdk8n3tPkI7wdOm3LFJIsfJvtBmszukDmPX9bQ-bfBkvm3Jsf_5B5fi_H_QQ7nfwkx228rIFK1g_gs3fSAm34fwDv7p6d8AmISqQTwLHBD2G0V1-REbPsSktj4Z9JJjKWp3gW7JFzT5TgY_FYicYNNAOXJ9O5sdT3qVc4FbksuFWodIODTrCsXGaOKM0KmdcWUqb5NpUOhZxSZgxUwZVZHK_8eayqEJRlliJx7BWL2p8AkxFaDLUVjibp47cUEs6PpWZES4lGIIjiPthL2zHR-7TYnwtgl8S5UWYtcLPWtHN2gjeDG2-tWwcd9be9kM-1OxGewR7_ewW3YL9USRKeK78TFDxq6GYlprfPzE1LpZUh8BaSnA31iPYbaVieHYvTE___s6XcG86n10UF2eX589gw_eyPROzB2vN9yU-J2TTlC-CQP8CmDXvJA |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Q-PPG%3A+Energy-Efficient+PPG-Based+Heart+Rate+Monitoring+on+Wearable+Devices&rft.jtitle=IEEE+transactions+on+biomedical+circuits+and+systems&rft.au=Burrello%2C+Alessio&rft.au=Pagliari%2C+Daniele+Jahier&rft.au=Risso%2C+Matteo&rft.au=Benatti%2C+Simone&rft.date=2021-12-01&rft.pub=The+Institute+of+Electrical+and+Electronics+Engineers%2C+Inc.+%28IEEE%29&rft.issn=1932-4545&rft.eissn=1940-9990&rft.volume=15&rft.issue=6&rft.spage=1196&rft_id=info:doi/10.1109%2FTBCAS.2021.3122017&rft.externalDBID=NO_FULL_TEXT |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1932-4545&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1932-4545&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1932-4545&client=summon |