Sensitivity of AMPLICOR MTB on direct detection of Mycobacterium tuberculosis in smear-negative specimens from outpatients in Rio de Janeiro

We evaluated the performance of the AMPLICOR MTB assay for detection of M. tuberculosis in clinical specimens obtained from 98 smear-negative tuberculous patients (43 with positive and 55 with negative culture results). The sensitivity of the AMPLICOR MTB was 44.9% (44/98) and that of culture was 43...

Full description

Saved in:
Bibliographic Details
Published inBrazilian journal of microbiology Vol. 33; no. 2; pp. 163 - 165
Main Authors Anjos Filho, Luciano dos(Universidade Federal do Rio de Janeiro Hospital Universitário Clementino Fraga Filho), Oelemann, Walter M.R.(Universidade Federal do Rio de Janeiro Centro de Ciências da Saúde Instituto de Microbiologia), Barreto, Clara E.N.(Secretaria Estadual de Saúde do Rio de Janeiro Laboratório Noel Nutels), Kritski, Afranio Lineu(Universidade Federal do Rio de Janeiro Hospital Universitário Clementino Fraga Filho), Fonseca, Leila de Souza(Universidade Federal do Rio de Janeiro Centro de Ciências da Saúde Instituto de Microbiologia)
Format Journal Article
LanguageEnglish
Published São Paulo Sociedade Brasileira de Microbiologia 01.06.2002
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We evaluated the performance of the AMPLICOR MTB assay for detection of M. tuberculosis in clinical specimens obtained from 98 smear-negative tuberculous patients (43 with positive and 55 with negative culture results). The sensitivity of the AMPLICOR MTB was 44.9% (44/98) and that of culture was 43.8% (43/98). No significant difference was observed between the results obtained by AMPLICOR MTB and by culture. We conclude that amplification assays could be used for testing smear-negative specimens because a rapid diagnosis will benefit those patients. A sensibilidade do kit AMPLICOR MTB foi avaliada em 98 espécimes clínicos baciloscopia negativa (43 eram cultura-positiva e 55 cultura-negativa) provenientes de pacientes ambulatoriais. A sensibilidade do AMPLICOR MTB foi de 44% (44/98) e a da cultura 43,8% (43/98). Não foi observada diferença significativa entre os resultados dos dois métodos. Conclui-se que os ensaios de amplificação podem ser utilizados em espécimes baciloscopia negativa, porque um rápido diagnóstico beneficiará esses pacientes.
Bibliography:http://www.scielo.br/scielo.php?script=sci_arttext&pid=S1517-83822002000200013
10.1590/S1517-83822002000200013
ISSN:1517-8382
1678-4405
1678-4405
1517-8382
DOI:10.1590/S1517-83822002000200013