Transcatheter Aortic Valve Implantation in Mixed Aortic Valve Disease: A Multicenter Study

Mixed aortic valve disease (MAVD), defined by the concurrent presence of aortic stenosis (AS) and insufficiency is frequently seen in patients who have undergone transcatheter aortic valve implantation (TAVI). However, studies comparing the outcomes of TAVI in MAVD versus isolated AS have demonstrat...

Full description

Saved in:
Bibliographic Details
Published inThe American journal of cardiology Vol. 203; pp. 394 - 402
Main Authors Guddeti, Raviteja R., Gill, Gauravpal S., Parekh, Jai D., Jhand, Aravdeep S., Walters, Ryan W., Panaich, Sidakpal S., Goldsweig, Andrew M., Alla, Venkata Mahesh
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 15.09.2023
Elsevier Limited
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Mixed aortic valve disease (MAVD), defined by the concurrent presence of aortic stenosis (AS) and insufficiency is frequently seen in patients who have undergone transcatheter aortic valve implantation (TAVI). However, studies comparing the outcomes of TAVI in MAVD versus isolated AS have demonstrated conflicting results. Therefore, we aim to assess the outcomes of TAVI in patients with MAVD in comparison with those with isolated severe AS. Patients who underwent native valve TAVI for severe AS at 3 tertiary care academic centers between January 2012 and December 2020 were included and categorized into 3 groups based on concomitant aortic insufficiency (AI) as follows: group 1, no AI; group 2, mild AI; and group 3, moderate to severe AI. Outcomes of interest included all-cause mortality and all-cause readmission rates at 30 days and 1 year. Other outcomes include bleeding, stroke, vascular complications, and the incidence of paravalvular leak at 30 days after the procedure. Of the 1,588 patients who underwent TAVI during the study period, 775 patients (49%) had isolated AS, 606 (38%) had mild AI, and 207 (13%) had moderate to severe AI. Society of Thoracic Surgeons risk scores were significantly different among the 3 groups (5% in group 1, 5.5% in group 2, and 6% in group 3, p = 0.003). Balloon-expandable valves were used in about 2/3 of the population. No statistically significant differences in 30-day or 1-year all-cause mortality and all-cause readmission rates were noted among the 3 groups. Post-TAVI paravalvular leak at follow-up was significantly lower in group 1 (2.3%) and group 2 (2%) compared with group 3 (5.6%) (p = 0.01). In summary, TAVI in MAVD is associated with comparable outcomes at 1 year compared with patients with isolated severe AS.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0002-9149
1879-1913
DOI:10.1016/j.amjcard.2023.07.064