Transthoracic measurement of left coronary artery flow reserve improves the diagnostic value of routine dipyridamole-atropine stress echocardiogram

We hypothesized that coronary flow reserve (CFR) in the left anterior descending artery (LAD) can be effectively measured during an accelerated dipyridamole-atropine stress echocardiography (DASE) protocol to improve the diagnostic performance of the test. In 64 patients with suspected or known coro...

Full description

Saved in:
Bibliographic Details
Published inArchives of medical science Vol. 9; no. 5; pp. 802 - 807
Main Authors Kasprzak, Jarosław D, Wejner-Mik, Paulina, Nouri, Aria, Szymczyk, Ewa, Krzemińska-Pakuła, Maria, Lipiec, Piotr
Format Journal Article
LanguageEnglish
Published Poland Termedia Publishing House 31.10.2013
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We hypothesized that coronary flow reserve (CFR) in the left anterior descending artery (LAD) can be effectively measured during an accelerated dipyridamole-atropine stress echocardiography (DASE) protocol to improve the diagnostic performance of the test. In 64 patients with suspected or known coronary artery disease scheduled for coronary angiography DASE with concomitant CFR measurement in LAD was performed. Coronary flow reserve measurement and calculation were feasible in 83% of patients. The positive predictive value of undetectable LAD flow was 81% for severe LAD disease. Measured values of CFR were in the range 1.3-4.1 (mean: 2.2 ±0.7). Significantly lower CFR was found in patients with LAD disease (1.97 ±0.62 vs. 2.55 ±0.57, p = 0.0015). The optimal cutoff for detecting ≥ 50% stenosis was CFR ≤ 2.1 (ROC AUC 0.776), corresponding with 68% sensitivity and 84% specificity. In patients with negative DASE results 67% of patients with LAD disease had abnormal CFR, whereas in patients with a positive DASE result 92% of patients with normal LAD had normal CFR. The DASE diagnostic accuracy for the detection of coronary artery disease (CAD) increased from 75% to 85% when CFR measurement was added to wall motion abnormality (WMA) analysis. No test with both abnormalities was false positive for the detection of coronary disease. Incorporation of CFR measurement into WMA-based stress echocardiography is feasible even in an accelerated DASE protocol and can be translated into an approximate gain of 10% in overall test accuracy.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1734-1922
1896-9151
DOI:10.5114/aoms.2013.38673