Qualification of a vertical cryostat for MLI performances tests between 20 K and 60 K to 4.2 K

Boil-off calorimetric measurements of Multilayer Insulation (MLI) performance from 20 K-60 K to 4.2 K are being performed at CERN, extending the range of measurements of MLI to cover cryostat applications where thermal shields are operated at lower temperatures than that of LN2. Possible application...

Full description

Saved in:
Bibliographic Details
Published inIOP conference series. Materials Science and Engineering Vol. 502; no. 1; pp. 12077 - 12081
Main Authors Venturi, V, Koettig, T, Chorowski, M, Polinski, J, Parma, V, Kopczynski, A
Format Journal Article
LanguageEnglish
Published Bristol IOP Publishing 01.04.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Boil-off calorimetric measurements of Multilayer Insulation (MLI) performance from 20 K-60 K to 4.2 K are being performed at CERN, extending the range of measurements of MLI to cover cryostat applications where thermal shields are operated at lower temperatures than that of LN2. Possible applications include future large accelerators like the Future Circular Collider (FCC). The tests are carried out in an existing vertical test cryostat shielded with a liquid nitrogen cooled vessel and with an inner cylindrical liquid helium tank carrying the wrapped MLI sample. The cryostat has been modified to insert an additional intermediate thermal shield maintained at controlled temperatures in the 20 K-60 K range, by means of regulated power input from an electrical heater. This paper describes the test cryostat and the MLI performance measurement methodology as well as experimental results of the commissioning and calibration of the instrument.
ISSN:1757-8981
1757-899X
1757-899X
DOI:10.1088/1757-899X/502/1/012077