Training and Validation of Deep Learning-Based Auto-Segmentation Models for Lung Stereotactic Ablative Radiotherapy Using Retrospective Radiotherapy Planning Contours

Deep learning-based auto-segmented contour (DC) models require high quality data for their development, and previous studies have typically used prospectively produced contours, which can be resource intensive and time consuming to obtain. The aim of this study was to investigate the feasibility of...

Full description

Saved in:
Bibliographic Details
Published inFrontiers in oncology Vol. 11; p. 626499
Main Authors Wong, Jordan, Huang, Vicky, Giambattista, Joshua A, Teke, Tony, Kolbeck, Carter, Giambattista, Jonathan, Atrchian, Siavash
Format Journal Article
LanguageEnglish
Published Switzerland Frontiers Media S.A 07.06.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Deep learning-based auto-segmented contour (DC) models require high quality data for their development, and previous studies have typically used prospectively produced contours, which can be resource intensive and time consuming to obtain. The aim of this study was to investigate the feasibility of using retrospective peer-reviewed radiotherapy planning contours in the training and evaluation of DC models for lung stereotactic ablative radiotherapy (SABR). Using commercial deep learning-based auto-segmentation software, DC models for lung SABR organs at risk (OAR) and gross tumor volume (GTV) were trained using a deep convolutional neural network and a median of 105 contours per structure model obtained from 160 publicly available CT scans and 50 peer-reviewed SABR planning 4D-CT scans from center A. DCs were generated for 50 additional planning CT scans from center A and 50 from center B, and compared with the clinical contours (CC) using the Dice Similarity Coefficient (DSC) and 95% Hausdorff distance (HD). Comparing DCs to CCs, the mean DSC and 95% HD were 0.93 and 2.85mm for aorta, 0.81 and 3.32mm for esophagus, 0.95 and 5.09mm for heart, 0.98 and 2.99mm for bilateral lung, 0.52 and 7.08mm for bilateral brachial plexus, 0.82 and 4.23mm for proximal bronchial tree, 0.90 and 1.62mm for spinal cord, 0.91 and 2.27mm for trachea, and 0.71 and 5.23mm for GTV. DC to CC comparisons of center A and center B were similar for all OAR structures. The DCs developed with retrospective peer-reviewed treatment contours approximated CCs for the majority of OARs, including on an external dataset. DCs for structures with more variability tended to be less accurate and likely require using a larger number of training cases or novel training approaches to improve performance. Developing DC models from existing radiotherapy planning contours appears feasible and warrants further clinical workflow testing.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
This article was submitted to Radiation Oncology, a section of the journal Frontiers in Oncology
Edited by: Jason W. Sohn, Allegheny Health Network, United States
Reviewed by: Jeonghoon Park, Memorial Sloan Kettering Cancer Center, United States; Min-Sig Hwang, University of Pittsburgh Medical Center, United States; Abdul Hussein Mroue, GenesisCare, United Kingdom
ISSN:2234-943X
2234-943X
DOI:10.3389/fonc.2021.626499