A 74-year-old woman had a 3-port pars plana vitrectomy for a dropped nucleus after complicated phacoemulsification. Flexible nylon iris retractors were positioned to dilate the small pupil. The patient died of a pulmonary embolus 1 day after surgery. The eyeball was removed at autopsy, and pathology...

Full description

Saved in:
Bibliographic Details
Published inJournal of cataract and refractive surgery Vol. 27; no. 10; pp. 1703 - 1705
Main Authors Tognetto, Daniele, Agolini, Giorgio, Grandi, Giorgio, Ravalico, Giuseppe
Format Journal Article
LanguageEnglish
Published New York, NY Elsevier Inc 01.10.2001
Elsevier Science
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A 74-year-old woman had a 3-port pars plana vitrectomy for a dropped nucleus after complicated phacoemulsification. Flexible nylon iris retractors were positioned to dilate the small pupil. The patient died of a pulmonary embolus 1 day after surgery. The eyeball was removed at autopsy, and pathology of the iris was investigated. Localized damage to the iris where the retractor hooks were positioned was noted, but no other alterations to the iris were observed. These findings may explain the recovery of pupil function that is common after surgery with mechanical iris retractors.