Analysis of flow field and temperature distribution in compact strip production casting process

A three-dimensional finite difference model has been formulated, using the commercial code CFX4, to describe the fluid flow and heat transfer in the funnel mould and secondary cooling segment of the compact strip production (CSP) casting process. Through simulation and computation with the establish...

Full description

Saved in:
Bibliographic Details
Published inIronmaking & steelmaking Vol. 34; no. 6; pp. 491 - 500
Main Authors Liu, X.-F., Zhang, J.-Y., Du, W.-D., Zhai, Q.-J., Li, Q.
Format Journal Article
LanguageEnglish
Published London, England Taylor & Francis 01.11.2007
SAGE Publications
Taylor & Francis Ltd
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:A three-dimensional finite difference model has been formulated, using the commercial code CFX4, to describe the fluid flow and heat transfer in the funnel mould and secondary cooling segment of the compact strip production (CSP) casting process. Through simulation and computation with the established simulation model, influences of the factors such as casting speed, casting superheat, immersion depth of submerged entrance nozzle, amount of cooling water in the secondary cooling segment on flow field and temperature field in the funnel mould and secondary cooling segment of CSP technology were analysed.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:0301-9233
1743-2812
DOI:10.1179/174328107X165681