Evaluating subconjunctival bleb function after trabeculectomy using slit-lamp optical coherence tomography and ultrasound biomicroscopy

Background The existing classifications for evaluating glaucoma filtering blebs rely mostly on external bleb characteristics and the postoperative control of intraocular pressure (IOP). Internal bleb structures are not carefully observed. This study aimed to analyze and compare glaucoma filtering bl...

Full description

Saved in:
Bibliographic Details
Published inChinese medical journal Vol. 121; no. 14; pp. 1274 - 1279
Main Authors Zhang, Yi, Wu, Qiang, Zhang, Min, Song, Bei-wen, DU, Xin-hua, Lu, Bin
Format Journal Article
LanguageEnglish
Published China 20.07.2008
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background The existing classifications for evaluating glaucoma filtering blebs rely mostly on external bleb characteristics and the postoperative control of intraocular pressure (IOP). Internal bleb structures are not carefully observed. This study aimed to analyze and compare glaucoma filtering bleb morphology using slit-lamp-adapted optical coherence tomography (SL-OCT) and ultrasound biomicroscopy (UBM), and to classify blebs according to results and intraocular pressure. Methods We followed 29 eyes of 21 male patients and 40 eyes of 32 female patients who underwent glaucoma filtering surgery in Sixth People's Hospital of Shanghai, between 2002 and 2006. The blebs were imaged using SL-OCT and UBM and classified according to the intrableb morphology and control of lOP after surgery. A Fisher's exact test was used to compare the sensitivity for predicting a functioning bleb differed significantly between SL-OCT and UBM. A Fisher's exact test was also used for morphological analysis of the trabeculectomy blebs based on SL-OCT. Results In the 69 eyes, there were 45 (65.2%) functioning blebs and 24 (34.8%) non-functioning blebs. We classified the blebs into four categories on the basis of SL-OCT images: diffuse, cystic, encapsulated and flat. Diffuse and cystic blebs were typically functional, whereas the other two types were always non-functional. The sensitivity of SL-OCT for predicting a functioning bleb was 92.7% (38/41 eyes) and specificity of predicting a non-functioning bleb was 83.3% (20/24 eyes). By contrast, sensitivity of UBM was 66.7% (30/45 eyes) and specificity was 75.0% (18/24 eyes). The sensitivity for predicting a functioning bleb differed significantly between the two techniques (P=0.003). Conclusions SL-OCT provides high-axial-resolution images of anterior segment structures. The non-contact approach of SL-OCT enables visualization of intrableb structures at any time after surgery. SL-OCT has greater sensitivity and specificity than UBM in evaluating filtering bleb function. The morphological classification supported the assessment of bleb function and could provide objective data for evaluating the outcome of antiglaucoma surgery or the need for a second procedure.
Bibliography:optical coherence tomography
ultrasonography
R775
glaucoma
11-2154/R
trabeculectomy
glaucoma; trabeculectomy; optical coherence tomography; ultrasonography
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0366-6999
2542-5641
DOI:10.1097/00029330-200807020-00005