Ultrasensitive colorimetric immunoassay for hCG detection based on dual catalysis of Au@Pt core–shell nanoparticle functionalized by horseradish peroxidase

In this paper, an ultrasensitive colorimetric biosensor for human chorionic gonadotrophin (hCG) detection was designed from bottom-up method based on the dual catalysis of the horseradish peroxidase (HRP) and Au@Pt nanoparticles (NPs) relative to H2O2-TEM system. HRP and monoclonal mouse anti-hCG an...

Full description

Saved in:
Bibliographic Details
Published inSpectrochimica acta. Part A, Molecular and biomolecular spectroscopy Vol. 193; pp. 102 - 108
Main Authors Wang, Weiguo, Zou, Yake, Yan, Jinwu, Liu, Jing, Chen, Huixiong, Li, Shan, Zhang, Lei
Format Journal Article
LanguageEnglish
Published England Elsevier B.V 15.03.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:In this paper, an ultrasensitive colorimetric biosensor for human chorionic gonadotrophin (hCG) detection was designed from bottom-up method based on the dual catalysis of the horseradish peroxidase (HRP) and Au@Pt nanoparticles (NPs) relative to H2O2-TEM system. HRP and monoclonal mouse anti-hCG antibody (β-submit, mAb1) were co-immobilized onto the Au@Pt NP surface to improve catalytic efficiency and specificity, which formed a dual functionalized Au@Pt-HRP probe with the mean size of 42.8nm (D50). The colorimetric immunoassay was developed for the hCG detection, and the Au@Pt-HRP probe featured a higher sensitivity in the concentration range of 0.4–12.8IUL−1 with a low limit of detection (LOD) of 0.1IUL−1 compared with the LODs of 0.8IUL−1 for BA-ELISA and of 2.0IUL−1 for Au@Pt, which indicated that the Au@Pt-HRP probe possessed higher catalytic efficiency with 2.8-fold increase over Au@Pt and 33.8-fold increase over HRP. Also, the Au@Pt-HRP probe exhibited good precision and reproducibility, high specificity and acceptable accuracy with CV being less than 15%. The dual functionalized Au@Pt-HRP probe as a type of signal amplified method was firstly applied in the colorimetric immunoassay for the hCG detection. [Display omitted] •The dual catalysis of Au@Pt-HRP probe was first applied in the colorimetric immunoassay for the hCG detection.•Au@Pt NPs was a good carrier for the signal amplification and about 21-22 HRP molecules could be absorbed on the surface of Au@Pt NP.•The Au@Pt-HRP probe featured a higher sensitivity in the concentration range of 0.4–12.8 IU L-1 with a LOD of 0.1 IU L-1.
ISSN:1386-1425
1873-3557
DOI:10.1016/j.saa.2017.12.014