Selective Cerebro-Myocardial Perfusion in Complex Congenital Aortic Arch Pathology: A Novel Technique

Simultaneous cerebro‐myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex...

Full description

Saved in:
Bibliographic Details
Published inArtificial organs Vol. 35; no. 11; pp. 1029 - 1035
Main Authors De Rita, Fabrizio, Lucchese, Gianluca, Barozzi, Luca, Menon, Tiziano, Faggian, Giuseppe, Mazzucco, Alessandro, Luciani, Giovanni Battista
Format Journal Article
LanguageEnglish
Published Malden, USA Blackwell Publishing Inc 01.11.2011
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Simultaneous cerebro‐myocardial perfusion has been described in neonatal and infant arch surgery, suggesting a reduction in cardiac morbidity. Here reported is a novel technique for selective cerebral perfusion combined with controlled and independent myocardial perfusion during surgery for complex or recurrent aortic arch lesions. From April 2008 to April 2011, 10 patients with arch pathology underwent surgery (two hypoplastic left heart syndrome [HLHS], four recurrent arch obstruction, two aortic arch hypoplasia + ventricular septal defect [VSD], one single ventricle + transposition of the great arteries + arch hypoplasia, one interrupted aortic arch type B + VSD). Median age was 63 days (6 days–36 years) and median weight 4.0 kg (1.6–52). Via midline sternotomy, an arterial cannula (6 or 8 Fr for infants) was directly inserted into the innominate artery or through a polytetrafluoroethylene (PTFE) graft (for neonates <2.0 kg). A cardioplegia delivery system was inserted into the aortic root. Under moderate hypothermia, ascending and descending aorta were cross‐clamped, and “beating heart and brain” aortic arch repair was performed. Arch repair was composed of patch augmentation in five, end‐to‐side anastomosis in three, and replacement in two patients. Average cardiopulmonary bypass time was 163 ± 68 min (71–310). In two patients only (one HLHS, one complex single ventricle), a period of cardiac arrest was required to complete intracardiac repair. In such cases, antegrade blood cardioplegia was delivered directly via the same catheter used for selective myocardial perfusion. Average time of splanchnic ischemia during cerebro‐myocardial perfusion was 39 ± 18 min (17–69). Weaning from cardiopulmonary bypass was achieved without inotropic support in three and with low dose in seven patients. One patient required veno‐arterial extracorporeal membrane oxygenation. Four patients, body weight <3.0 kg, needed delayed sternal closure. No neurologic dysfunction was noted. Renal function proved satisfactory in all, while liver function was adequate in all but one. The present experience suggests that selective and independent cerebro‐myocardial perfusion is feasible in patients with complex or recurrent aortic arch disease, starting from premature newborn less than 2.0 kg of body weight to adults. The technique is as safe as previously reported methods of cerebro‐myocardial perfusion and possibly more versatile.
Bibliography:istex:C3C2DA20515F87D1B1F29DC9879252C2A8C25713
ark:/67375/WNG-9GSTPQFQ-9
ArticleID:AOR1355
Presented in part at the 7th International Conference on Pediatric Mechanical Circulatory Support Systems and Pediatric Cardiopulmonary Perfusion held May 5–7, 2011 in Philadelphia, PA, USA.