Feasibility of a sub‐3‐minute imaging strategy for ungated quiescent interval slice‐selective MRA of the extracranial carotid arteries using radial k‐space sampling and deep learning–based image processing

Purpose To develop and test the feasibility of a sub‐3‐minute imaging strategy for non‐contrast evaluation of the extracranial carotid arteries using ungated quiescent interval slice‐selective (QISS) MRA, combining single‐shot radial sampling with deep neural network–based image processing to optimi...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 84; no. 2; pp. 825 - 837
Main Authors Koktzoglou, Ioannis, Huang, Rong, Ong, Archie L., Aouad, Pascale J., Aherne, Emily A., Edelman, Robert R.
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.08.2020
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.28179

Cover

More Information
Summary:Purpose To develop and test the feasibility of a sub‐3‐minute imaging strategy for non‐contrast evaluation of the extracranial carotid arteries using ungated quiescent interval slice‐selective (QISS) MRA, combining single‐shot radial sampling with deep neural network–based image processing to optimize image quality. Methods The extracranial carotid arteries of 12 human subjects were imaged at 3 T using ungated QISS MRA. In 7 healthy volunteers, the effects of radial and Cartesian k‐space sampling, single‐shot and multishot image acquisition (1.1‐3.3 seconds/slice, 141‐423 seconds/volume), and deep learning–based image processing were evaluated using segmental image quality scoring, arterial temporal SNR, arterial‐to‐background contrast and apparent contrast‐to‐noise ratio, and structural similarity index. Comparison of deep learning–based image processing was made with block matching and 3D filtering denoising. Results Compared with Cartesian sampling, radial k‐space sampling increased arterial temporal SNR 107% (P < .001) and improved image quality during 1‐shot imaging (P < .05). The carotid arteries were depicted with similar image quality on the rapid 1‐shot and much lengthier 3‐shot radial QISS protocols (P = not significant), which was corroborated in patient studies. Deep learning–based image processing outperformed block matching and 3D filtering denoising in terms of structural similarity index (P < .001). Compared with original QISS source images, deep learning image processing provided 24% and 195% increases in arterial‐to‐background contrast (P < .001) and apparent contrast‐to‐noise ratio (P < .001), and provided source images that were preferred by radiologists (P < .001). Conclusion Rapid, sub‐3‐minute evaluation of the extracranial carotid arteries is feasible with ungated single‐shot radial QISS, and benefits from the use of deep learning–based image processing to enhance source image quality.
Bibliography:Funding information
National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health; Grant/Award Number R01EB027475
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.28179