TMIS: a new image‐based software application for the measurement of tear meniscus height

Purpose To present a new automated image recognition software for the measurement of tear meniscus height (TMH) and investigate its correlation and efficacy compared with an open‐source software (NIH ImageJ) and manual evaluation. Methods A total of 520 slit lamp photographs, among which 276 were in...

Full description

Saved in:
Bibliographic Details
Published inActa ophthalmologica (Oxford, England) Vol. 97; no. 7; pp. e973 - e980
Main Authors Yang, Jiarui, Zhu, Xingyu, Liu, Yushi, Jiang, Xiaodan, Fu, Jiayu, Ren, Xiaotong, Li, Kaixiu, Qiu, Weiqiang, Li, Xuemin, Yao, Jun
Format Journal Article
LanguageEnglish
Published England Wiley Subscription Services, Inc 01.11.2019
Subjects
Online AccessGet full text
ISSN1755-375X
1755-3768
1755-3768
DOI10.1111/aos.14107

Cover

More Information
Summary:Purpose To present a new automated image recognition software for the measurement of tear meniscus height (TMH) and investigate its correlation and efficacy compared with an open‐source software (NIH ImageJ) and manual evaluation. Methods A total of 520 slit lamp photographs, among which 276 were in ×16 magnification and 244 were ×40 magnified, captured from 138 eyes of 69 healthy subjects were assessed for TMH by the new automated Tear Meniscus Identification Software (TMIS), ImageJ and human graders. Images processing of TMIS included filtration, recognition and measurement of slit lamp photographs under certain algorithm, which output two measurement patterns, TMISMax and TMISMean. TMH measured by ImageJ software, considered as the reference value, was conducted by a masked observer while four masked ophthalmologists performed the manual evaluation. Results In both magnifications, TMH measured by TMISMean showed similar values with ImageJ while manual evaluation demonstrated underestimated results, and a strong correlation was detected between TMIS and ImageJ. In ×16 magnified photographs, manually obtained TMH revealed a higher correlation with ImageJ, whereas a notably stronger correlation of TMIS with ImageJ was observed in ×40 photographs. Correspondingly, the accuracy for both TMISMax and TMISMean appeared to be lower than most doctors in ×16 slit lamp images, in contrast to a better precision of TMISMean in ×40 ones. Conclusion The new software displayed high accuracy and efficacy in ×40 magnification and TMISMean pattern, suggesting the possibility of this automated TMH measurement platform to be a valid tool in dry eye screening and follow‐up practice.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1755-375X
1755-3768
1755-3768
DOI:10.1111/aos.14107