An investigation into the minimum number of tissue groups required for 7T in‐silico parallel transmit electromagnetic safety simulations in the human head

Purpose Safety limits for the permitted specific absorption rate (SAR) place restrictions on pulse sequence design, especially at ultrahigh fields (≥ 7 tesla). Due to intersubject variability, the SAR is usually conservatively estimated based on standard human models that include an applied safety m...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 85; no. 2; pp. 1114 - 1122
Main Authors Buck, Matthijs H. S., Jezzard, Peter, Jeong, Hongbae, Hess, Aaron T.
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.02.2021
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.28467

Cover

More Information
Summary:Purpose Safety limits for the permitted specific absorption rate (SAR) place restrictions on pulse sequence design, especially at ultrahigh fields (≥ 7 tesla). Due to intersubject variability, the SAR is usually conservatively estimated based on standard human models that include an applied safety margin to ensure safe operation. One approach to reducing the restrictions is to create more accurate subject‐specific models from their segmented MR images. This study uses electromagnetic simulations to investigate the minimum number of tissue groups required to accurately determine SAR in the human head. Methods Tissue types from a fully characterized electromagnetic human model with 47 tissue types in the head and neck region were grouped into different tissue clusters based on the conductivities, permittivities, and mass densities of the tissues. Electromagnetic simulations of the head model inside a parallel transmit head coil at 7 tesla were used to determine the minimum number of required tissue clusters to accurately determine the subject‐specific SAR. The identified tissue clusters were then evaluated using 2 additional well‐characterized electromagnetic human models. Results A minimum of 4‐clusters‐plus‐air was found to be required for accurate SAR estimation. These tissue clusters are centered around gray matter, fat, cortical bone, and cerebrospinal fluid. For all 3 simulated models, the parallel transmit maximum 10g SAR was consistently determined to within an error of <12% relative to the full 47‐tissue model. Conclusion A minimum of 4‐clusters‐plus‐air are required to produce accurate personalized SAR simulations of the human head when using parallel transmit at 7 tesla.
Bibliography:Funding information
p.j.
The Wellcome Centre for Integrative Neuroimaging is supported by core funding from the Wellcome Trust, grant 203139/Z/16/Z. We also thank the Dunhill Medical Trust and the NIHR Oxford Biomedical Research Centre for support
[Correction added after online publication 1 September 2020. Due to a publisher's error, Equation 1 was corrected to remove the text “volumeTOTO” and add “volume” to the limits of the integral].
acknowledges support from the BHF Centre of Research Excellence, Oxford, grant RE/13/1/30181
.
a.t.h.
[Correction added after online publication 29 October 2020. The affiliation ‘Department of Radiology, Harvard Medical School, Boston, Maryland, USA’ has been changed to Department of Radiology, Harvard Medical School, Boston, Massachusetts, USA].
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.28467