'Wrong-way-round ionization' and screening for doping substances in human urine by high-performance liquid chromatography/orbitrap mass spectrometry
To free analytical resources for new classes of doping substances, such as banned proteins, maximization of the number of compounds that can be determined with high sensitivity in a single run is highly urgent. This study demonstrates an application of ‘wrong‐way‐round ionization’ for the simultaneo...
Saved in:
Published in | Journal of mass spectrometry. Vol. 47; no. 3; pp. 381 - 391 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
Chichester, UK
John Wiley & Sons, Ltd
01.03.2012
Wiley |
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | To free analytical resources for new classes of doping substances, such as banned proteins, maximization of the number of compounds that can be determined with high sensitivity in a single run is highly urgent. This study demonstrates an application of ‘wrong‐way‐round ionization’ for the simultaneous detection of multiple classes of doping substances without the need to switch the polarity. A screening method for the detection of 137 compounds from various classes of prohibited substances (stimulants, diuretics, β2‐agonists, β‐blockers, antiestrogens, glucocorticosteroids and anabolic agents) has been developed. The method involves an enzymatic hydrolysis, liquid–liquid extraction and detection by liquid chromatography/orbitrap mass spectrometry with wrong‐way‐round ionization. Up to 64% of compounds had a 10‐fold lower limit of detection (LOD) than the minimum required performance limit. To compare the efficiency of conventional ionization relative to wrong‐way‐round ionization of doping substances in + ESI, a fortified blank urine sample at the minimum required performance limit was analyzed using two ESI approaches. All compounds were detected with markedly better S/N in a high‐pH mobile phase, with the exception of acetazolamide (minimal change in S/N, < 20%).The method was validated by spiking 10 different blank urine samples at five different concentrations. Validation parameters included the LOD, selectivity, ion suppression, extraction recovery and repeatability. Copyright © 2012 John Wiley & Sons, Ltd. |
---|---|
Bibliography: | istex:D60AA74F10562D4EDCC3E449AA4C3FB71C13444D World Anti-Doping Agency - No. 09A11GR ArticleID:JMS2055 ark:/67375/WNG-7Z7VBQZL-Z ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
ISSN: | 1076-5174 1096-9888 |
DOI: | 10.1002/jms.2055 |