Controlling motion artefact levels in MR images by suspending data acquisition during periods of head motion

Purpose Head movements are a major source of MRI artefacts. Prospective motion correction techniques significantly improve data quality, but strong motion artefacts may remain in the data. We introduce a framework to suspend data acquisition during periods of head motion over a predefined threshold....

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 80; no. 6; pp. 2415 - 2426
Main Authors Castella, Rémi, Arn, Lionel, Dupuis, Estelle, Callaghan, Martina F., Draganski, Bogdan, Lutti, Antoine
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.12.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose Head movements are a major source of MRI artefacts. Prospective motion correction techniques significantly improve data quality, but strong motion artefacts may remain in the data. We introduce a framework to suspend data acquisition during periods of head motion over a predefined threshold. Methods Data was acquired with prospective motion correction and an external optical tracking system. A predictor of motion impact was introduced that accounts for the amplitude of the signal acquired at the time of the motion. From this predictor, a threshold was defined to trigger the suspension of data acquisition during periods of motion. The framework was tested on 5 subjects, 2 motion behaviors, and 2 head coils (20 and 64 channels). Results The best improvements in data quality were obtained for a threshold value of 0, equivalent to suspending the acquisition based on head speed alone, at the cost of a long prolongation of scan time. For threshold values ∼3.5e−4, image quality was largely preserved, and prolongation of scan time was minimal. Artefacts occasionally remained with the 64‐channel head coil for all threshold values, seemingly due to head movement in the sharp sensitivity profile of this coil. Conclusion The proposed suspension strategy is more efficient than relying on head speed alone. The threshold for suspension of data acquisition governs the tradeoff between image degradation due to motion and prolonged scan time, and can be tuned by the user according to the desired image quality and participant's tolerability.
Bibliography:Funding information
These authors contributed equally to this work.
Supported by the Roger De Spoelberch Foundation and the Partridge Foundation. A.L. is supported by the Roger De Spoelberch Foundation. B.D. is supported by the Swiss National Science Foundation (NCCR Synapsy, project grant 32003B_159780), Foundation Parkinson Switzerland, and Foundation Synapsis. The research leading to these results has received funding from the European Union's Horizon 2020 Research and Innovation Program under grant agreement 720270 (HBP SGA1)
The copyright line for this article was changed on 22 December 2018 after original online publication.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.27214