Influence of windowing and metal artefact reduction algorithms on the volumetric dimensions of five different high-density materials: a cone-beam CT study

To assess the influence of windowing and metal artefact reduction (MAR) algorithms on the volumetric dimensions of high-density materials using two CBCT systems. Four cylinders of amalgam, cobalt-chromium, gutta-percha, titanium and zirconium, were manufactured and their physical volumes (PV) were m...

Full description

Saved in:
Bibliographic Details
Published inDento-maxillo-facial radiology Vol. 49; no. 8; p. 20200039
Main Authors Coelho-Silva, Fernanda, Martins, Luciano Augusto Cano, Braga, Daniela Azeredo, Zandonade, Eliana, Haiter-Neto, Francisco, de-Azevedo-Vaz, Sergio Lins
Format Journal Article
LanguageEnglish
Published England The British Institute of Radiology 01.12.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To assess the influence of windowing and metal artefact reduction (MAR) algorithms on the volumetric dimensions of high-density materials using two CBCT systems. Four cylinders of amalgam, cobalt-chromium, gutta-percha, titanium and zirconium, were manufactured and their physical volumes (PV) were measured. A polymethyl methacrylate phantom containing the cylinders was submitted to CBCT acquisitions with Picasso Trio and OP300 units with their MAR enabled and disabled. The tomographic volume (TV) of all the cylinders was obtained by semi-automatic segmentation using two windowing adjustments: W1-large window width and upper window level; W2-narrow window width and low window level. Volumetric distortion was expressed as the difference between TV and PV. Statistics comprised intraclass correlation coefficient (ICC) and analysis of variance (ANOVA) for repeated measures with Tukey test (α = 5%). The ICC values ​​indicated excellent reproducibility of TV. Gutta-percha and titanium resulted in the smallest volumetric distortion. Using W1 provided less volumetric distortion for almost all experimental conditions ( < 0.05). Activating MAR algorithm of Picasso Trio underestimated gutta-percha and titanium TV ( < 0.05) and was inefficient in significantly reducing the volumetric distortion of the other materials ( > 0.05). Disabling MAR algorithm of OP300 resulted in smaller volumetric distortion for almost all experimental conditions ( < 0.05). The TV of gutta-percha and titanium were closer to the PV. In general, the MAR algorithms of both systems were inefficient in significantly reducing the volumetric distortion of high-density materials. We encourage the use of large window width and upper window level to evaluate high-density materials.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0250-832X
1476-542X
DOI:10.1259/DMFR.20200039