Evaluating Descriptive Metrics of the Human Cone Mosaic

To evaluate how metrics used to describe the cone mosaic change in response to simulated photoreceptor undersampling (i.e., cell loss or misidentification). Using an adaptive optics ophthalmoscope, we acquired images of the cone mosaic from the center of fixation to 10° along the temporal, superior,...

Full description

Saved in:
Bibliographic Details
Published inInvestigative ophthalmology & visual science Vol. 57; no. 7; pp. 2992 - 3001
Main Authors Cooper, Robert F., Wilk, Melissa A., Tarima, Sergey, Carroll, Joseph
Format Journal Article
LanguageEnglish
Published United States The Association for Research in Vision and Ophthalmology 01.06.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To evaluate how metrics used to describe the cone mosaic change in response to simulated photoreceptor undersampling (i.e., cell loss or misidentification). Using an adaptive optics ophthalmoscope, we acquired images of the cone mosaic from the center of fixation to 10° along the temporal, superior, inferior, and nasal meridians in 20 healthy subjects. Regions of interest (n = 1780) were extracted at regular intervals along each meridian. Cone mosaic geometry was assessed using a variety of metrics - density, density recovery profile distance (DRPD), nearest neighbor distance (NND), intercell distance (ICD), farthest neighbor distance (FND), percentage of six-sided Voronoi cells, nearest neighbor regularity (NNR), number of neighbors regularity (NoNR), and Voronoi cell area regularity (VCAR). The "performance" of each metric was evaluated by determining the level of simulated loss necessary to obtain 80% statistical power. Of the metrics assessed, NND and DRPD were the least sensitive to undersampling, classifying mosaics that lost 50% of their coordinates as indistinguishable from normal. The NoNR was the most sensitive, detecting a significant deviation from normal with only a 10% cell loss. The robustness of cone spacing metrics makes them unsuitable for reliably detecting small deviations from normal or for tracking small changes in the mosaic over time. In contrast, regularity metrics are more sensitive to diffuse loss and, therefore, better suited for detecting such changes, provided the fraction of misidentified cells is minimal. Combining metrics with a variety of sensitivities may provide a more complete picture of the integrity of the photoreceptor mosaic.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
RC's Current affiliation: Departments of Ophthalmology and Psychology, University of Pennsylvania, Philadelphia, Pennsylvania, United States.
ISSN:1552-5783
0146-0404
1552-5783
DOI:10.1167/iovs.16-19072