Macular SD-OCT Outcome Measures: Comparison of Local Structure-Function Relationships and Dynamic Range

We tested the hypothesis that the macular ganglion cell layer (GCL) thickness demonstrates a stronger structure-function (SF) relationship and extends the useful range of macular measurements compared with combined macular inner layer or full thickness. Ninety-eight glaucomatous eyes and eight norma...

Full description

Saved in:
Bibliographic Details
Published inInvestigative ophthalmology & visual science Vol. 57; no. 11; pp. 4815 - 4823
Main Authors Miraftabi, Arezoo, Amini, Navid, Morales, Esteban, Henry, Sharon, Yu, Fei, Afifi, Abdolmonem, Coleman, Anne L, Caprioli, Joseph, Nouri-Mahdavi, Kouros
Format Journal Article
LanguageEnglish
Published United States The Association for Research in Vision and Ophthalmology 01.09.2016
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We tested the hypothesis that the macular ganglion cell layer (GCL) thickness demonstrates a stronger structure-function (SF) relationship and extends the useful range of macular measurements compared with combined macular inner layer or full thickness. Ninety-eight glaucomatous eyes and eight normal eyes with macular spectral domain optical coherence tomography (SD-OCT) volume scans and 10-2 visual fields were enrolled. Inner plexiform layer (IPL), GCL, macular retinal nerve fiber layer (mRNFL), ganglion cell-inner plexiform layer (GCIPL), ganglion cell complex (GCC), and full thickness (FT) measurements were calculated for 8 × 8 arrays of 3° superpixels. Main outcome measures were local structure-function relationships between macular superpixels and corresponding sensitivities on 10-2 fields after adjusting for ganglion cell displacement, dynamic range of measurements, and the change point (total deviation value where macular parameters reached measurement floor). Median (interquartile range [IQR]) mean deviation was -7.2 (-11.6 to -3.2) dB in glaucoma eyes. Strength of SF relationships was highest for GCIPL, GCL, GCC, and IPL (ρ = 0.635, 0.627, 0.621, and 0.577, respectively; P ≤ 0.046 for comparisons against GCIPL). Highest SF correlations coincided with the peak of GCL thickness, where the dynamic range was widest for FT (81.1 μm), followed by GCC (65.7 μm), GCIPL (54.9 μm), GCL (35.2 μm), mRNFL (27.5 μm), and IPL (20.9 μm). Change points were similar for all macular parameters (-7.8 to -8.9 dB). GCIPL, GCL, and GCC demonstrated comparable SF relationships while FT, GCC, and GCIPL had the widest dynamic range. Measurement of GCL did not extend the range of useful structural measurements. Measuring GCL does not provide any advantage for detection of progression with current SD-OCT technology.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1552-5783
0146-0404
1552-5783
DOI:10.1167/iovs.16-19648