Development and evaluation of a robust algorithm for computer-assisted detection of sentinel lymph node micrometastases

Clarke G M, Peressotti C, Holloway C M B, Zubovits J T, Liu K & Yaffe M J
(2011) Histopathology59, 116–128 Development and evaluation of a robust algorithm for computer‐assisted detection of sentinel lymph node micrometastases Aims:  Increasing the sectioning rate for breast sentinel lymph nodes...

Full description

Saved in:
Bibliographic Details
Published inHistopathology Vol. 59; no. 1; pp. 116 - 128
Main Authors Clarke, Gina M, Peressotti, Chris, Holloway, Claire M B, Zubovits, Judit T, Liu, Kela, Yaffe, Martin J
Format Journal Article
LanguageEnglish
Published Oxford, UK Blackwell Publishing Ltd 01.07.2011
Blackwell
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Clarke G M, Peressotti C, Holloway C M B, Zubovits J T, Liu K & Yaffe M J
(2011) Histopathology59, 116–128 Development and evaluation of a robust algorithm for computer‐assisted detection of sentinel lymph node micrometastases Aims:  Increasing the sectioning rate for breast sentinel lymph nodes can increase the likelihood of detecting micrometastases. To make serial sectioning feasible, we have developed an algorithm for computer‐assisted detection (CAD) with digitized lymph node sections. Methods and results:  K‐means clustering assigned image pixels to one of four areas in a colourspace (representing tumour, unstained background, counterstained background and microtomy artefacts). Four filters then removed ‘false‐positive’ pixels from the tumour cluster. A set of 43 sections containing tumour (a total of 259 foci) and 59 sections negative for malignancy was defined by two pathologists, using light microscopy, and CAD was applied. For the clinically relevant task of identifying the largest focus in each section (micrometastasis in 22/43 sections), the sensitivity and specificity were 100%. Isolated tumour cells (ITCs) were identified in one slide initially considered to be negative. Identification of all 259 foci yielded sensitivities of 57.5% for ITCs (<0.200 mm), 89.5% for micrometastases, and 100% for larger metastases, with one false‐positive. Reduced sensitivity was ascribed to variable staining. Nine additional metastases (<0.01–0.3 mm) that were not initially identified were detected by CAD. Conclusions:  This algorithm is well suited to the task of sentinel lymph node evaluation and may enhance the detection of occult micrometastases.
Bibliography:ark:/67375/WNG-P0FTQCCG-7
istex:D5115A9BBCF1C896243322A3D75556A3FCBB77FF
ArticleID:HIS3896
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0309-0167
1365-2559
DOI:10.1111/j.1365-2559.2011.03896.x