Analysis of blood hete levels by selected ion monitoring with ricinoleic acid as the internal standard

Selected ion monitoring of mass fragments of peaks from capillary gas chromatograms permits a sensitive and selective analysis of positional isomers of hydroxy-eicosanoids (as their methyl ester, trimethylsilyl ether derivatives). Because deuterated analogs of these HETEs are not readily available,...

Full description

Saved in:
Bibliographic Details
Published inProstaglandins Vol. 34; no. 5; pp. 733 - 748
Main Authors Walenga, Ronald W., Boone, Sherry, Stuart, Marie J.
Format Journal Article
LanguageEnglish
Published Stoneham, MA Elsevier Inc 01.11.1987
Butterworth-Heinemann
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Selected ion monitoring of mass fragments of peaks from capillary gas chromatograms permits a sensitive and selective analysis of positional isomers of hydroxy-eicosanoids (as their methyl ester, trimethylsilyl ether derivatives). Because deuterated analogs of these HETEs are not readily available, stable isotope dilution cannot be easily performed. We have developed a method for the quantitation of HETEs using ricinoleci acid (12-hydroxy-oleic acid) as an internal standard. Ricinoleic acid is monitored at m/z 187, while 5-, 12- and 15-HETEs (those commonly found in biological systems) are not monitored at m/z 255, 295 and 225 respectively. The procedure has proven linear for levels from 0.03 to >3.0 nmol HETE per nmol standard. There is however significant “crossover” among the HETEs, requiring preliminary resolution of the various isomers by reverse phase HPLC in samples containing more than one HETE. Recovery of authentic standards added to various blood samples through the extraction, resolution and analyses averaged over 90%. Using this procedure, mean plasma concentrations were found to be less than 0.1 uM for all HETEs tested, while serum levels were approximately 0.3, 0.8 and 0.1 uM for 5-, 12- and 15-HETE respectively. Serum formed in the presence of 2mM arachidonic acid plus 25 uM A23187, to maximize HETE production, contained an average of 4, 22 and 1 uM 5-, 12- and 15-HETE respectively. Thus while normal human plasma contains sufficient quantities of the various HETEs to produce some of the biological effects attributed to these metabolites, there is potential for an even greater production when sufficient substrate is available.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0090-6980
DOI:10.1016/0090-6980(87)90296-6