Quantification of Two Aromatic Amine Mutagens, PBTA-1 and PBTA-2, in the Yodo River System
The levels of two aromatic amine mutagens, 2-[2-(acetylamino)-4-[bis(2-methoxyethyl)amino]-5-methoxyphenyl]-5-amino-7-bromo-4-chloro-2H-benzotriazole (PBTA-1) and 2-[2-(acetylamino-4-[N-(2-cyanoethyl)ethylamino]-5-methoxyphenyl]-5-amino-7-bromo-4-chloro-2H-benzotriazole (PBTA-2), were quantitatively...
Saved in:
Published in | Environmental health perspectives Vol. 107; no. 9; pp. 701 - 704 |
---|---|
Main Authors | , , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
United States
National Institute of Environmental Health Sciences. National Institutes of Health. Department of Health, Education and Welfare
01.09.1999
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | The levels of two aromatic amine mutagens, 2-[2-(acetylamino)-4-[bis(2-methoxyethyl)amino]-5-methoxyphenyl]-5-amino-7-bromo-4-chloro-2H-benzotriazole (PBTA-1) and 2-[2-(acetylamino-4-[N-(2-cyanoethyl)ethylamino]-5-methoxyphenyl]-5-amino-7-bromo-4-chloro-2H-benzotriazole (PBTA-2), were quantitatively analyzed in the Yodo River system in Japan. The river water samples were collected at nine sampling sites from the Yodo River system twice or three times between May and July in 1997. PBTA-1 and PBTA-2 in the river water samples were concentrated on blue rayon columns, partially purified by high-performance liquid chromatography (HPLC) on reverse-phase columns, then quantified by HPLC with an electrochemical detector. The amounts of PBTA-1 and PBTA-2 in the water samples were < 0.01-1.91 and < 0.01-2.25 ng/L, respectively. High levels of PBTA-1 and PBTA-2 were detected in the samples collected within 4 km downstream of two sewage plants, which are located along the banks of the Nishitakase River, a tributary of the Yodo River system, and these samples showed stronger mutagenicity in Salmonella typhimurium YG1024 with S9 mix than the other water samples. On the other hand, the river water samples from upstream of the sewage plant were weakly or not mutagenic and PBTA-1 and PBTA-2 were not detected. These results confirmed that a major source of PBTA-1 and PBTA-2 in the Yodo River system is effluent from the sewage plants and that discharged mutagens, including PBTA-1 and PBTA-2, are diluted and/or decomposed while moving down the Yodo River system. |
---|---|
Bibliography: | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Feature-1 content type line 23 |
ISSN: | 0091-6765 1552-9924 |
DOI: | 10.1289/ehp.99107701 |