Activation analysis in vivo using 5 MeV incident neutrons

Activation analysis using 5 MeV incident neutrons has been considered as a method for estimating whole-body sodium, chlorine and calcium in humans. Experiments with irradiated phantoms have shown that adequate uniformity of thermal neutron activation could be achieved in most subjects, though when t...

Full description

Saved in:
Bibliographic Details
Published inThe International journal of applied radiation and isotopes Vol. 20; no. 1; pp. 61 - 68
Main Authors Newton, D., Anderson, J., Battye, C.K., Osborn, S.B., Tomlinson, R.W.S.
Format Journal Article
LanguageEnglish
Published United States Elsevier B.V 1969
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Activation analysis using 5 MeV incident neutrons has been considered as a method for estimating whole-body sodium, chlorine and calcium in humans. Experiments with irradiated phantoms have shown that adequate uniformity of thermal neutron activation could be achieved in most subjects, though when the incident neutron energy was reduced to 2.5 MeV, serious non-uniformities arose. With 5 MeV incident neutrons, no difficulties are expected from the interfering activities induced by the fast flux when 14 MeV sources are employed. The method has been applied succesfully to the analysis of small animals. On a considéré l'analyse par activation utilisant les neutrons incidents de 5 MeV comme méthode pour le dosage du sodium, du chlore et du calcium du corps entierdans les humains. Des expériences avec des phantômes irradiés ont montré qu'on pouvait achever une uniformité suffisante d'activation par neutrons thermiques dans la plupart des sujets, quoique, lors de la diminution de l'énergie neutronique incidente à 2,5 MeV, il apparǔt de graves non-uniformités. Avec des neutrons incidents de 5 MeV on n'attend aucune difficulté à cause des activités interférantes qui sont induites par le flux rapide lorsqu'on emploie des sources de 14 MeV. On a porté avec du succès la méthode á l'analyse des petits animaux. Для oпpeдeлehля oc;meгo coдepжahля b ыelcy;obeыecкom opгahлэme haтpля, xлopa л кaльцля c;ыл выc;paнмeтoд aктлвaцлoммoгo aнaлйэa S; пймeнeйeм нoc;oKhcy;ныx нeйтpнoв c; 5 мeгaэлeктpoнвoльт. Oпыыы e oy;лyKhcy;eнныни фaнтoмaми пoкaэaлл, Khcy;тo в c;oль-щинS;твe S;лyKhcy;aeв вoэмoжнo пoлyKhcy;icy;ть дoS;тaтoKhcy;нo eдинooc;paэнyю aктивaцию тeПлoвыx нeйтpoнoв, xoты пpи S;нижeнии энepгии пoc;oKhcy;ныx нeйтpoнoв дo 2,5 мeгaэлeктpoнвoльт вoэникaли cepьeэныe нeeдинooc;paэиы. C пoc;oKhcy;ными нeйтpoxaми в 5 мeгaэлeктpoнвoльт нe вoэникaeт никaкиx эaтoyднeний oт пoмex, выэывaeмыx c;ыcтpым пoтoкoм, кoгдa иcпoльэyютcн итoKhcy;ники в 14 мeгaэлeктpoнвoлbt. Этoт мeтoд ycпeшнo пpимeняeтcя длы иcпытaнй нa нec;oлf;шиx живoтныx. Aktivierungsanalynsen unter Verwendung von 5 MeV Einfallsneutronen werden in Ewägunggezogen als Verfahren zum Abschätzen des Natrium, Chlor und Kalzium im ganzen menschlichen Körper. Versuche mit bestrahlten Phantomen haben gezeigt, dass ausreichen Gleichmässigkeit der thermischen Neutronenaktivierung in dem meisten Objekten erreicht werden konnte, aber dass ernstliche Ungleichmässigkeiten auftraten, wenn die Neutroneneinfallsenergie auf 2,5 MeV fiel. Keine Schwiergkkeiten werden erwartet bei 5 MeV Einfallsneutronen von den Störtätigkeiten, die von dem schnellen Fluss bei Anwendung von 14 MeV Quellen induziert werden. Das Verfahren wurde mit Erfolg verwendet für die Analyse von Kleintieren.
ISSN:0020-708X
DOI:10.1016/0020-708X(69)90167-7