The Suitability of Trabecular Patterns in the Assessment of Dental Implant Osseointegration Process through 2D Digital and 3D CBCT Radiographs

The research aims to determine the suitability of the trabecular pattern in the assessment of the dental implant osseointegration process through two-dimensional (2D) digital and three-dimensional (3D) cone-beam computed tomography (CBCT) radiographs.  This is a correlation description that explains...

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of dentistry Vol. 18; no. 2; pp. 571 - 578
Main Authors Putri, Annisa, Pramanik, Farina, Azhari, Azhari
Format Journal Article
LanguageEnglish
Published Germany Thieme Medical and Scientific Publishers Pvt. Ltd 01.05.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The research aims to determine the suitability of the trabecular pattern in the assessment of the dental implant osseointegration process through two-dimensional (2D) digital and three-dimensional (3D) cone-beam computed tomography (CBCT) radiographs.  This is a correlation description that explains the relationship between variables. The population consisted of 24 data points on 3D CBCT and 2D digital radiographs from the procedure after dental implants were inserted into the tibia of a New Zealand white rabbit ( ) on days 3, 14, and 28. The radiograph was selected based on the region of interest (ROI), which covers the peri-implant area with a width of 1 mm and length following the height of the implant. The ROI was analyzed for trabecular thickness (Tb.Th), separation (Tb.Sp), number (Tb.N), and fractal dimension.  The intraclass correlation coefficient (ICC) was used to statistically test the data to assess the consistency of intraobserver measurements and the value (Pearson's correlation coefficient). This determines the correlation between trabecular patterns in both radiographic modalities and the Bland-Altman plot to observe the limits of acceptable discrepancies.  The ICC test showed high intraobserver consistency in trabecular pattern measurements on 2D digital radiographs and 3D CBCT. The trabecular space pattern and number showed an value of 0.88 with radiographic modalities of 0.72 mm and 0.018, respectively. Additionally, the trabecular thickness and fractal dimension had an insignificant correlation, with an value of 0.22, and the mean of the 2D radiograph was lower than that of CBCT.  The 2D radiograph and 3D CBCT showed correlations in the trabecular number and space results but had no correlation in the trabecular thickness and fractal dimension results. Based on intraclass correlation analysis, 3D CBCT appeared to be more reliable for measuring trabecular patterns (Tb.Th, Tb.Sp, Tb.N, and fractal dimension) than 2D radiograph.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1305-7456
1305-7464
DOI:10.1055/s-0043-1772570