Retrospective analysis of reduced energy switching and room switching times on throughput efficiency of a multi-room proton therapy center

To quantify how a control software upgrade changed beam delivery times and impacted efficiency and capacity of a multiroom proton therapy center. A four-room center treating approximately 90 patients/day, treating for approximately 7 years with optimized operations, underwent a software upgrade whic...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of radiology Vol. 93; no. 1107; p. 20190820
Main Authors Mah, Dennis, Chen, Chin Cheng, Nawaz, A Omer, Galbreath, Greg, Shmulenson, Reuven, Lee, Nancy, Chon, Brian
Format Journal Article
LanguageEnglish
Published England The British Institute of Radiology 01.03.2020
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To quantify how a control software upgrade changed beam delivery times and impacted efficiency and capacity of a multiroom proton therapy center. A four-room center treating approximately 90 patients/day, treating for approximately 7 years with optimized operations, underwent a software upgrade which reduced room and energy switching times from approximately 30 to 20 s and approximately 4 s to ~0.5 s, respectively. The center uses radio-frequency identification data to track patient treatments and has software which links this to beam delivery data extracted from the treatment log server. Two 4-month periods, with comparable patient volume, representing periods before and after the software change, were retrospectively analyzed. A total of 16,168 and 17,102 fields were analyzed. For bilateral head and neck and prostate patients, the beam waiting time was reduced by nearly a factor of 3 and the beam delivery times were reduced by nearly a factor of 2.5. Room switching times were reduced more modestly. Gantry capacity has increased from approximately 30 patients to 40-45 patients in a 16-h daily operation. Many proton centers are striving for increased efficiencies. We demonstrated that reductions in energy and room switching time can significantly increase center capacity. Greater potential for further gains would come from improvements in setup and imaging efficiency. This paper provides detailed measured data on the effect on treatment times resulting from reducing energy and room switching times under controlled conditions. It helps validate the models of previous investigations to establish treatment capacity of a proton therapy center.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0007-1285
1748-880X
DOI:10.1259/bjr.20190820