Repeatability and reproducibility of apparent diffusion coefficient and fat fraction measurement of focal myeloma lesions on whole body magnetic resonance imaging

To assess intra- and inter-reader variability of apparent diffusion coefficient (ADC) and fat fraction (FF) measurement in focal myeloma bone lesions and the influence of lesion size. 22 myeloma patients with focal active disease on whole body MRI were included. Two readers outlined a small (5-10 mm...

Full description

Saved in:
Bibliographic Details
Published inBritish journal of radiology Vol. 94; no. 1120; p. 20200682
Main Authors Barwick, Tara, Orton, Matthew, Koh, Dow Mu, Kaiser, Martin, Rockall, Andrea, Tunariu, Nina, Blackledge, Matthew, Messiou, Christina
Format Journal Article
LanguageEnglish
Published England The British Institute of Radiology 01.04.2021
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:To assess intra- and inter-reader variability of apparent diffusion coefficient (ADC) and fat fraction (FF) measurement in focal myeloma bone lesions and the influence of lesion size. 22 myeloma patients with focal active disease on whole body MRI were included. Two readers outlined a small (5-10 mm) and large lesion (>10 mm) in each subject on derived ADC and FF maps; one reader performed this twice. Intra- and inter-reader agreement for small and large lesion groups were calculated for derived statistics from each map using within-subject standard deviation, coefficient of variation, interclass correlation coefficient measures, and visualized with Bland-Altman plots. For mean ADC, intra- and inter-reader repeatability demonstrated equivalently low coefficient of variation (3.0-3.6%) and excellent interclass correlation coefficient (0.975-0.982) for both small and large lesions. For mean FF, intra- and inter-reader repeatability was significantly poorer for small lesions compared to large lesions (intra-reader within-subject standard variation estimate is 2.7 times higher for small lesions than large lesions ( = 0.0071), and for inter-reader variations is 3.8 times higher ( = 0.0070)). There is excellent intra- and inter-reader agreement for mean ADC estimates, even for lesions as small as 5 mm. For FF measurements, there is a significant increase in coefficient of variation for smaller lesions, suggesting lesions >10 mm should be selected for lesion FF measurement. ADC measurements of focal myeloma have excellent intra- and inter-reader agreement. FF measurements are more susceptible to lesion size as intra- and inter-reader agreement is significantly impaired in lesions less than 10 mm.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0007-1285
1748-880X
1748-880X
DOI:10.1259/bjr.20200682