Sleep apnea assessment using declination duration-based global metrics from unobtrusive fiber optic sensors

Objective: Sufficient sleep helps to restore the immune, nervous and cardiovascular systems, but is sometimes disturbed by sleep apnea (SA). The early diagnosis of sleep apnea is beneficial for the prevention of diseases. Polysomnography (PSG) recording provides comprehensive data for such assessmen...

Full description

Saved in:
Bibliographic Details
Published inPhysiological measurement Vol. 40; no. 7; p. 075005
Main Authors Hsu, Ming-Hung, Fang, Shih-Chin, Wang, Fu-Tai, Chan, Hsiao-Lung, Huang, Hsiu-En, Yang, Shu-Chen
Format Journal Article
LanguageEnglish
Published England IOP Publishing 30.07.2019
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Objective: Sufficient sleep helps to restore the immune, nervous and cardiovascular systems, but is sometimes disturbed by sleep apnea (SA). The early diagnosis of sleep apnea is beneficial for the prevention of diseases. Polysomnography (PSG) recording provides comprehensive data for such assessment, but is not suitable for use at home due to discomfort during measurement and the difficulty of identification. This study proposes an unobtrusive measurement process by placing fiber optic sensors (FOSs) in a pillow (head-neck) or a bed mattress (thoracic-dorsal). Approach: We test two approaches: drop degrees from the baseline to validate the capability of catching respiratory drops, and linear regression models based on a new global measure, the percentage of the total duration of respiratory declination (PTDRD), to estimate the hand-scored apnea/hypopnea index (AHI). Main results: Based on data recorded from 63 adults, the drop degrees derived from respiratory signals exhibited statistical differences among central sleep apnea (CSA), obstructive sleep apnea (OSA) and normal breathing. The regression models based on the PTDRDs derived from head-neck FOS and thoracic-dorsal FOS also achieved good agreement with manually scored AHIs in Bland-Altman plots as well as oronasal airflow and thoracic wall movement. Significance: The aforementioned performance demonstrates the capability of the FOS measurement and the efficacy of the PTDRD metrics for SA assessment.
Bibliography:Institute of Physics and Engineering in Medicine
PMEA-102990.R2
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0967-3334
1361-6579
1361-6579
DOI:10.1088/1361-6579/ab21b5