Direct and absolute temperature mapping and heat transfer measurements in diode-end-pumped Yb:YAG

We report on direct and absolute temperature measurements in a diode-end-pumped Yb:YAG crystal, using a calibrated infrared camera, with a 60 {/content/F3TMHDJUVGCD3EGE/xxlarge956.gif}m spatial resolution. The heat transfer coefficient has been measured, for the first time to our knowledge, with fou...

Full description

Saved in:
Bibliographic Details
Published inApplied physics. B, Lasers and optics Vol. 79; no. 2; pp. 221 - 224
Main Authors CHENAIS, S, FORGET, S, DRUON, F, BALEMBOIS, F, GEORGES, P
Format Journal Article
LanguageEnglish
Published Berlin Springer 01.07.2004
Springer Verlag
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:We report on direct and absolute temperature measurements in a diode-end-pumped Yb:YAG crystal, using a calibrated infrared camera, with a 60 {/content/F3TMHDJUVGCD3EGE/xxlarge956.gif}m spatial resolution. The heat transfer coefficient has been measured, for the first time to our knowledge, with four different types of thermal contact (H=0.2,0.2,0.9, and 2.0 for bare contact, graphite layer, indium foil, and heat sink grease respectively). The dynamics of thermal effects are also presented.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0946-2171
1432-0649