A double-blind, randomized, sham-controlled trial of the effect of a radiation-attenuating drape on radiation exposure to endoscopy staff during ERCP

Endoscopic retrograde cholangiopancreatography (ERCP) is associated with radiation exposure to the endoscopist and staff that may be significant in high-volume centers. We investigated whether a radiation-attenuating drape over the fluoroscopy image intensifier reduces radiation exposure during ERCP...

Full description

Saved in:
Bibliographic Details
Published inThe American journal of gastroenterology Vol. 110; no. 5; pp. 690 - 696
Main Authors Muniraj, Thiruvengadam, Aslanian, Harry R, Laine, Loren, Farrell, James, Ciarleglio, Maria M, Deng, Yanhong, Ho, Henry, Jamidar, Priya A
Format Journal Article
LanguageEnglish
Published United States Wolters Kluwer Health Medical Research, Lippincott Williams & Wilkins 01.05.2015
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Endoscopic retrograde cholangiopancreatography (ERCP) is associated with radiation exposure to the endoscopist and staff that may be significant in high-volume centers. We investigated whether a radiation-attenuating drape over the fluoroscopy image intensifier reduces radiation exposure during ERCP. We performed a prospective, randomized, double-blind trial of 100 therapeutic ERCPs at a tertiary-care university center. Procedures were randomly assigned to groups receiving lead-free radiation-attenuating drapes (n=50) or identical sham drapes (n=50). The drapes were suspended around the fluoroscopy image intensifier during ERCP. The primary end point was the effective dose of radiation measured at the endoscopist's eye and neck, and at the assisting nurse's neck. The cumulative annual radiation exposure was also estimated. Fluoroscopy time, absorbed radiation dose, and dose area product were similar in the study groups. Mean effective dose for sham vs. radiation-attenuating drape was 0.21±0.27 vs. 0.02±0.02 mSv at the endoscopist's eye, 0.35±0.44 vs. 0.03±0.03 mSv at the endoscopist's neck, and 0.27±0.34 vs. 0.02±0.02 mSv at the nurse's neck (P<0.0001 for all comparisons). The relative risk reduction in radiation was 90%, 91%, and 93% at the three sites. At a high-volume center in which an endoscopist performs 500 therapeutic ERCPs per year, the estimated cumulative annual effective dose at the endoscopist's eye level is 126 mSv with conventional protection and 12 mSv with a radiation-attenuating drape, with the recommended limit being 20 mSv. The addition of a radiation-attenuating drape around the image intensifier during ERCP significantly decreases radiation exposure to endoscopists and staff by ∼90%.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-News-1
ObjectType-Feature-3
content type line 23
ISSN:0002-9270
1572-0241
DOI:10.1038/ajg.2015.85