Full-Scale Fire Test of an Intercity Train Car

Fire development inside a train car is a topic that has not been studied extensively due to the complexity of the problem and the need for a real train car and the appropriate facilities to conduct these tests in a controlled environment. This paper presents detailed experimental data on fire develo...

Full description

Saved in:
Bibliographic Details
Published inFire technology Vol. 52; no. 5; pp. 1559 - 1574
Main Authors Lee, Duck Hee, Park, Won Hee, Hwang, Jungho, Hadjisophocleous, George
Format Journal Article
LanguageEnglish
Published New York Springer US 01.09.2016
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Fire development inside a train car is a topic that has not been studied extensively due to the complexity of the problem and the need for a real train car and the appropriate facilities to conduct these tests in a controlled environment. This paper presents detailed experimental data on fire development inside a real intercity train car. The facility used for the tests is capable of conducting such large-scale fires and measuring the heat release rate using oxygen consumption calorimetry. Thermocouples and plate thermometers were installed inside the train car to provide an insight of the fire development. A number of cameras were also placed inside the car and in the tunnel providing live videos during the test. The peak heat release rate was 32 MW at 1081 s after ignition, and the fire burned 83% of the initial fire load. Flame spread data and recordings of window breaking events are discussed and compared to the heat release rate data. A local flashover-type phenomenon where the fire involved all combustibles at the rear of the car was found to occur.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0015-2684
1572-8099
DOI:10.1007/s10694-015-0482-1