Evaluation of assays for nucleic acid testing for the prevention of chikungunya and dengue virus transmission by blood transfusion

Background The large dengue (DENV) and chikungunya (CHIKV) outbreaks observed during the last decade across the world, as well as local transmissions in non‐endemic areas are a growing concern for blood safety. The aim of this study was to evaluate and compare the sensitivity of nucleic acid tests (...

Full description

Saved in:
Bibliographic Details
Published inTransfusion (Philadelphia, Pa.) Vol. 64; no. 8; pp. 1503 - 1508
Main Authors Gallian, Pierre, Dupont, Isabelle, Lacoste, Marjorie, Brisbarre, Nadège, Isnard, Christine, Delouane, Idriss, Richard, Pascale, Morel, Pascal, Laperche, Syria, Lamballerie, Xavier
Format Journal Article
LanguageEnglish
Published Hoboken, USA John Wiley & Sons, Inc 01.08.2024
Wiley Subscription Services, Inc
Wiley
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background The large dengue (DENV) and chikungunya (CHIKV) outbreaks observed during the last decade across the world, as well as local transmissions in non‐endemic areas are a growing concern for blood safety. The aim of this study was to evaluate and compare the sensitivity of nucleic acid tests (NAT) detecting DENV and CHIKV RNA. Materials and Methods Using DENV 1 to 4 International Standards, the limits of detection (LODs) calculated by probit analysis of two NAT assays; the cobas CHIKV/DENV assay (Roche Diagnostics) and the Procleix Dengue Virus Assay (Grifols) were compared. In addition, CHIKV‐RNA LOD of the cobas CHIKV/DENV assay was evaluated. Results For dengue, the 95% LOD of the cobas assay ranged between 4.10 [CI95%: 2.70–8.19] IU/mL (DENV‐2) and 7.07 [CI95%: 4.34–14.89] IU/mL (DENV‐4), and between 2.19 [CI95%: 1.53–3.83] IU/mL (DENV‐3) and 5.84 [CI95%: 3.84–10.77] IU/mL (DENV‐1) for Procleix assay. The Procleix assay had a significant lower LOD for DENV‐3 (2.19 vs. 5.89 IU/mL) when compared to the cobas assay (p = 0.005). The 95% LOD for CHIKV‐RNA detection of the cobas assay was 4.76 [CI95%: 3.08–8.94] IU/mL. Discussion The two NAT assays developed for blood donor screening evaluated in this study demonstrated high and similar analytical performance. Subject to an appropriate risk‐benefit assessment, they can be used to support blood safety during outbreaks in endemic areas or in non‐endemic areas as an alternative to deferring blood donors during local transmission likely to affect the blood supply. The development of multiplex assays is expected to optimize laboratory organization.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ObjectType-Undefined-3
ISSN:0041-1132
1537-2995
1537-2995
DOI:10.1111/trf.17921