A Comparison of Postoperative Throat and Neck Complaints After the Use of the i-gel® and the La Premiere® Disposable Laryngeal Mask: A Double-Blinded, Randomized, Controlled Trial
Many supralaryngeal airway devices are available. Because of the absence of an inflatable cuff, we hypothesized that use of the i-gel should produce fewer postoperative throat and neck complaints compared with a standard disposable laryngeal mask (LM). Two hundred eighteen patients were randomized t...
Saved in:
Published in | Anesthesia and analgesia Vol. 109; no. 4; pp. 1092 - 1094 |
---|---|
Main Authors | , , , , , , , , |
Format | Journal Article |
Language | English |
Published |
Hagerstown, MD
Lippincott Williams & Wilkins
01.10.2009
|
Subjects | |
Online Access | Get full text |
Cover
Loading…
Summary: | Many supralaryngeal airway devices are available. Because of the absence of an inflatable cuff, we hypothesized that use of the i-gel should produce fewer postoperative throat and neck complaints compared with a standard disposable laryngeal mask (LM).
Two hundred eighteen patients were randomized to have either an i-gel or La Premiere LM airway placed for airway management. Patients were interviewed postoperatively for throat and neck complaints at 1, 24, and 48 h. Interviewers and patients were blinded to the device used.
One hundred nine patients had an i-gel and 103 had a La Premiere supraglottic device inserted. The incidence of sore throat was significantly lower with the i-gel than with LM at 1 (6 vs 32), 24 (7 vs 48), and 48 h (5 vs 25). Similar results were seen for dysphagia. The incidence of neck pain was also lower for the i-gel at 24 (1 vs 7) and 48 h (1 vs 7).
In this randomized study, the i-gel supraglottic device resulted in a lower incidence of throat and neck complaints than the La Premiere LM airway. |
---|---|
ISSN: | 0003-2999 1526-7598 |
DOI: | 10.1213/ANE.0b013e3181b6496a |