Interscanner reproducibility of cardiovascular magnetic resonance T2 measurements of tissue iron in thalassemia

Purpose To assess interscanner reproducibility of tissue iron measurements in patients with thalassemia using gradient echo T2* measurements on two different MRI scanners. Materials and Methods Twenty‐five patients with thalassemia major had liver and myocardial T2* assessment using a Picker Edge 1....

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetic resonance imaging Vol. 18; no. 5; pp. 616 - 620
Main Authors Westwood, Mark A., Anderson, Lisa J., Firmin, David N., Gatehouse, Peter D., Lorenz, Christine H., Wonke, Beatrix, Pennell, Dudley J.
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.11.2003
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To assess interscanner reproducibility of tissue iron measurements in patients with thalassemia using gradient echo T2* measurements on two different MRI scanners. Materials and Methods Twenty‐five patients with thalassemia major had liver and myocardial T2* assessment using a Picker Edge 1.5T Scanner and a Siemens Sonata 1.5T scanner, with similar gradient echo sequences. In a subset of 13 patients, two scans on the Siemens scanner were performed to assess interstudy reproducibility. Results There was a highly significant, linear correlation between T2* values obtained for both the heart (r = 0.95) and the liver (r = 0.99) between scanners. The mean difference, coefficient of variability, and 95% confidence intervals between scanners were 0.8 msec, 9.4% and –5.0 to 6.7 msec for the heart; and 0.9 msec, 7.9% and –2.0 to 3.9 msec for the liver. The interstudy mean difference and coefficient of variability on the Siemens scanner was 0.3 msec and 4.8% (r = 0.99) for the heart, and 0.04 msec and 1.9% (r = 0.99) for the liver. Conclusion The T2* technique for measuring tissue iron is reproducible between the two manufacturers' scanners. This suggests that the widespread implementation of the technique is possible for clinical assessment of myocardial iron loading in thalassemia. J. Magn. Reson. Imaging 2003;18:616–620. © 2003 Wiley‐Liss, Inc.
Bibliography:istex:DB05828B23615B3C926DB7BBC77496CB7B201D9A
CORDA (The Heart Charity)
British Heart Foundation
ArticleID:JMRI10396
ark:/67375/WNG-F6SJRHF3-P
Siemens Medical Solutions
Wellcome Trust
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1053-1807
1522-2586
DOI:10.1002/jmri.10396