Feasibility of Conduction System Pacing in Patients with Baseline Bundle Branch Block-A Single-Center Mid-Term Follow-Up Study

The primary prerequisite for a successful conduction system pacing (CSP) procedure is the integrity of the conduction system, which may be impaired if a baseline bundle branch block (BBB) is present. This study aimed to evaluate the feasibility and mid-term performance of permanent CSP in patients w...

Full description

Saved in:
Bibliographic Details
Published inJournal of clinical medicine Vol. 13; no. 2; p. 454
Main Authors Pestrea, Catalin, Rusu, Marcela, Enache, Roxana, Cicala, Ecaterina, Gavrilescu, Radu, Vaduva, Adrian, Ortan, Florin, Iorgulescu, Corneliu, Vatasescu, Radu
Format Journal Article
LanguageEnglish
Published Switzerland MDPI AG 01.01.2024
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The primary prerequisite for a successful conduction system pacing (CSP) procedure is the integrity of the conduction system, which may be impaired if a baseline bundle branch block (BBB) is present. This study aimed to evaluate the feasibility and mid-term performance of permanent CSP in patients with baseline BBB and to compare the results between left bundle branch block (LBBB) and right bundle branch block (RBBB) patterns. A total of 101 patients with typical BBB and an attempt at CSP were retrospectively reviewed. Procedural characteristics, pacing, sensing parameters, and complications at baseline and after a mid-term follow-up were analyzed. The global procedural success for CSP was 93%. His bundle pacing (HBP) had a significantly lower success rate than left bundle branch area pacing (LBBAP) (50.5% vs. 86%). The paced QRS duration was significantly narrower with HBP. The pacing and sensing thresholds were significantly better with LBBAP. Procedural complications occurred only in the LBBAP group (two acute perforations in the LV cavity and one acute chest pain during lead fixation) without long-term sequelae. The HBP and the LBBAP procedural success rates were higher in the RBBB versus the LBBB group (62.5% vs. 44.9% and 100% vs. 81.5%, respectively). Baseline QRS duration, atrial volumes, and right ventricular diameters were significantly associated with HBP procedural failure. The follow-up pacing and sensing thresholds were similar to the baseline values for all pacing methods and BBB morphology. Only one device-related complication leading to pacing interruption was recorded. In patients with bundle branch blocks, CSP is a feasible procedure associated with a high success rate, stable pacing and sensing parameters, and low complication rates over a mid-term follow-up.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2077-0383
2077-0383
DOI:10.3390/jcm13020454