A hook effect-free immunochromatographic assay (HEF-ICA) for measuring the C-reactive protein concentration in one drop of human serum

The immunochromatographic (ICA) assay is a highly promising platform for rapid and simple detection of C-reactive protein (CRP) which is an indicator of the different phases of various diseases, as well as of inflammation and infection. However, the hook effect in the ICA assay limits the quantifica...

Full description

Saved in:
Bibliographic Details
Published inTheranostics Vol. 8; no. 12; pp. 3189 - 3197
Main Authors Oh, Jusung, Joung, Hyou-Arm, Han, Hyung Soo, Kim, Jong Kun, Kim, Min-Gon
Format Journal Article
LanguageEnglish
Published Australia Ivyspring International Publisher 01.01.2018
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:The immunochromatographic (ICA) assay is a highly promising platform for rapid and simple detection of C-reactive protein (CRP) which is an indicator of the different phases of various diseases, as well as of inflammation and infection. However, the hook effect in the ICA assay limits the quantification of CRP levels at high CRP concentrations. In this study, we developed a hook effect-free immunochromatographic assay (HEF-ICA) to detect CRP over a wide concentration range. The hook effect results from the simultaneous reaction of an excess target antigens with both immobilized and labeled antibodies respectively. To reduce the potential occurrence of this simultaneous reaction, we separated the migration of the target antigen and gold nanoparticle (AuNP)-labeled antibodies on a nitrocellulose membrane and analyzed the time profiles by modifying the ICA structure. The signal intensity of HEF-ICA was saturated at high CRP concentrations, without decreasing. The titration curve of HEF-ICA was adjusted with the Hill equation, and HEF-ICA was performed with the following parameters: limit of detection, 43 ng mL ; dynamic range, 119 ng mL to 100 µg mL . The accuracy of the newly developed assay was evaluated using 33 clinical samples via comparison with a clinical chemistry analyzer. HEF-ICA enabled the measurement of a wide range of CRP concentrations without the hook effect, and was suitable for point-of-care testing with fingertip blood sampling, as only a minute sample volume (2.5 µL) was required.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
These authors contributed equally to this work.
Competing Interests: The authors have declared that no competing interest exists.
ISSN:1838-7640
1838-7640
DOI:10.7150/thno.24034