Passive and active cooling for the outdoor built environment – Analysis and assessment of the cooling potential of mitigation technologies using performance data from 220 large scale projects

•The average peak temperature drop from mitigation techniques is close to 2K.•The decrease of the average ambient temperature is close to 0.74K.•Almost 31% of the projects resulted in a peak temperature drop below 1K and 62% below 2K. Local and global climate change increases the ambient temperature...

Full description

Saved in:
Bibliographic Details
Published inSolar energy Vol. 154; pp. 14 - 33
Main Authors Santamouris, M., Ding, L., Fiorito, F., Oldfield, P., Osmond, Paul, Paolini, R., Prasad, D., Synnefa, A.
Format Journal Article
LanguageEnglish
Published New York Elsevier Ltd 15.09.2017
Pergamon Press Inc
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:•The average peak temperature drop from mitigation techniques is close to 2K.•The decrease of the average ambient temperature is close to 0.74K.•Almost 31% of the projects resulted in a peak temperature drop below 1K and 62% below 2K. Local and global climate change increases the ambient temperature of cities by several degrees with important consequences on energy consumption, health and the economy. Advanced urban mitigation technologies contribute to decrease the ambient temperature and counterbalance the impact of urban heat islands. The present paper analyses and presents in a comparative way the mitigation potential of the known mitigation technologies using performance data from about 220 real scale urban rehabilitation projects. The average and peak temperature drop of reflective technologies, greenery, evaporative systems, earth to air heat exchangers and their combinations is calculated and presented. The mitigation potential of the main systems like cool roofs, cool pavements, green roofs, urban trees, pools and ponds, sprinklers, fountains, and evaporative towers, is analysed. It is found that the potential of the main mitigation technologies is considerable and can counterbalance UHI effects partly or fully. The average peak temperature drop calculated for all projects is close to 2K, while the corresponding decrease of the average ambient temperature is close to 0.74K. Almost 31% of the analysed projects resulted in a peak temperature drop below 1K, 62% below 2K, 82% below 3K and 90% below 4K.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0038-092X
1471-1257