Microbubble-augmented Ultrasound Declotting of Thrombosed Arteriovenous Dialysis Grafts in Dogs

Transcutaneous low-frequency ultrasound (LFUS) can effectively lyse clots in the presence of microbubbles. This study was designed to test the commercially available human albumin microspheres injectable suspension octafluoropropane formulation, Optison, to establish efficacy and assess US parameter...

Full description

Saved in:
Bibliographic Details
Published inJournal of vascular and interventional radiology Vol. 14; no. 3; pp. 343 - 347
Main Authors Culp, William C., Porter, Thomas R., McCowan, Timothy C., Roberson, Paula K., James, Charles A., Matchett, W. Jean, Moursi, Mohammed
Format Journal Article
LanguageEnglish
Published United States Elsevier Inc 01.03.2003
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Transcutaneous low-frequency ultrasound (LFUS) can effectively lyse clots in the presence of microbubbles. This study was designed to test the commercially available human albumin microspheres injectable suspension octafluoropropane formulation, Optison, to establish efficacy and assess US parameters of intensity and wave modes in a canine model of a thrombosed arteriovenous (dialysis) graft. Arteriovenous grafts in five dogs were cannulated, temporarily ligated, and thrombosed. Different declotting techniques were randomized to treat nine groups. Control groups involved direct saline (4.5 mL) clot injection in 0.5–1.0-mL increments. One group underwent peripheral intravenous microbubble injection (13.5 mL). Six groups underwent direct incremental clot injection of 4.5 mL of microspheres with LFUS for 30 minutes in 3–5-minute increments with use of various intensity settings in continuous-wave and pulsed-wave (PW) modes. At each increment, angiography was used to grade flow, declotting, and overall success. One hundred four procedures showed success in all 24 high-intensity PW modes (1.2–2.0 W/cm 2); only one of 20 control experiments was successful ( P < .0001). Medium-intensity modes yielded intermediate success rates. Lowest-intensity direct-injection groups and intravenous and control groups ranked lower. Results at 30 minutes were better than at 15 minutes ( P < .0001). LFUS with direct injection of microbubbles is effective in lysing moderate-sized clots and recanalizing thrombosed arteriovenous grafts. It best succeeds at the higher range of intensity settings tested in PW mode. Further development is justified.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1051-0443
1535-7732