Objective cataract grading methods and expected contrast sensitivity reestablishment with multifocal intraocular lenses

Purpose To determine the cut-off points for age and metrics provided by cataract grading objective systems for which a reestablishment in contrast sensitivity (CS) is expected after multifocal intraocular lens (MIOL) implantation. Methods One hundred seven subjects were included in this retrospectiv...

Full description

Saved in:
Bibliographic Details
Published inInternational ophthalmology Vol. 43; no. 8; pp. 2825 - 2832
Main Authors Fernández, Joaquín, Burguera, Noemí, Rocha-de-Lossada, Carlos, Rachwani-Anil, Rahul, Rodríguez-Vallejo, Manuel
Format Journal Article
LanguageEnglish
Published Dordrecht Springer Netherlands 01.08.2023
Springer Nature B.V
Subjects
Online AccessGet full text
ISSN1573-2630
0165-5701
1573-2630
DOI10.1007/s10792-023-02680-8

Cover

More Information
Summary:Purpose To determine the cut-off points for age and metrics provided by cataract grading objective systems for which a reestablishment in contrast sensitivity (CS) is expected after multifocal intraocular lens (MIOL) implantation. Methods One hundred seven subjects were included in this retrospective analysis carried out during the screening for presbyopia and cataract surgery. Monocular distance corrected contrast sensitivity defocus curve (CSDC) and visual acuity were measured, and crystalline lens sclerosis was graded with three objective metrics: Ocular Scatter Index (OSI), Dysfunctional Lens Index (DLI) and Pentacam Nucleus Staging (PNS). A CS value of 0.8 logCS at far distance, following published literature on this matter, was selected to compute the cut-off that maximized the detection of eyes exceeding this value at the preoperative screening, either for age or objective metrics. Results The CDCS showed a stronger correlation than CDVA with objective grading methods, whereas all objective metrics were significantly correlated between them ( p  < 0.05). The cut-offs for age, OSI, DLI and PNS were ≤ 62, ≤ 1.25, ≥ 7.67 and ≤ 1, respectively. The OSI provided the highest area under the receiver operating characteristic curve (0.85) followed by the age (0.84), DLI (0.74) and PNS (0.63). Conclusions Surgeons conducting clear lens exchange should communicate the possible distance CS loss after surgery with MIOL implantation according to the previous described cut-offs points. Age in combination with any cataract grading objective system is recommended to detect possible inconsistencies.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1573-2630
0165-5701
1573-2630
DOI:10.1007/s10792-023-02680-8