Urothelial-phase thin-section MDCT of the bladder in patients with hematuria: added value of multiplanar reformatted images

Purpose To evaluate the diagnostic performance of MDCT with axial images and multiplanar reformatted (MPR) images from the urothelial phase of the bladder in patients with hematuria using cystoscopy as the reference standard. Materials and methods Our IRB for human investigation approved this study,...

Full description

Saved in:
Bibliographic Details
Published inAbdominal imaging Vol. 46; no. 5; pp. 2025 - 2031
Main Authors Han, Byoung Hee, Park, Sung Bin, Chang, In Ho, Chi, Byung Hoon, Park, Hyun Jeong, Lee, Eun Sun
Format Journal Article
LanguageEnglish
Published New York Springer US 01.05.2021
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose To evaluate the diagnostic performance of MDCT with axial images and multiplanar reformatted (MPR) images from the urothelial phase of the bladder in patients with hematuria using cystoscopy as the reference standard. Materials and methods Our IRB for human investigation approved this study, and informed consent was waived. We included 192 patients (121 men, 71 women; age range 17–90 years; mean age ± SD: 60 ± 14 years) who underwent contrast-enhanced MDCT (scan delay: 70 s; section thickness: 2 mm) and conventional cystoscopy examination for painless gross hematuria or recurrent microscopic hematuria. Two radiologists in consensus interpreted the images for the presence or absence of bladder lesions. Using the kappa statistic, the patient-based agreement was determined between the CT and cystoscopic findings. We compared the diagnostic performance of axial images to those with coronal and sagittal reformations to detect bladder lesions. Results MDCT showed excellent agreement between cystoscopy–axial scans ( κ  = 0.896) and axial with reformatted images ( κ  = 0.948). The sensitivity, specificity, and accuracy of MDCT were 94%, 96%, and 95% in the axial scans and 98%, 97%, and 97% in the axial with reformatted images, respectively. All statistical parameters of diagnostic performance were similar between the axial and the reformatted images ( p  > .05). Conclusion Axial MDCT imaging demonstrates high diagnostic performance in detecting bladder lesions, but additional reformatted images can improve diagnostic accuracy.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:2366-004X
2366-0058
DOI:10.1007/s00261-020-02819-6