Correlation between intraocular pressure obtained with water drinking test versus modified diurnal tension curve measurement in pseudoexfoliation glaucoma

Purpose The aim of this paper was to study the correlation and agreement between the intraocular pressure (IOP) peak value and fluctuations detected with the modified diurnal tension curve (mDTC) and the water drinking test (WDT) in pseudoexfoliation glaucoma (XFG) patients. Methods This prospective...

Full description

Saved in:
Bibliographic Details
Published inInternational ophthalmology Vol. 41; no. 8; pp. 2879 - 2886
Main Authors Firat, Penpe Gül, Dikci, Seyhan, Firat, İlknur Tuncer, Demirel, Soner, Firat, Murat, Öztürk, Emrah, Gök, Zarife Ekici
Format Journal Article
LanguageEnglish
Published Dordrecht Springer Netherlands 01.08.2021
Springer Nature B.V
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Purpose The aim of this paper was to study the correlation and agreement between the intraocular pressure (IOP) peak value and fluctuations detected with the modified diurnal tension curve (mDTC) and the water drinking test (WDT) in pseudoexfoliation glaucoma (XFG) patients. Methods This prospective observational study enrolled 42 eyes of 42 XFG patients. The IOPs were measured at 2-h intervals from 8 am to 4 pm with a Goldmann applanation tonometer by a single observer to establish the mDTC. The WDT was then performed between 4 and 5 pm on the same day and the IOP was measured 4 times at 15-min intervals after water ingestion. The IOP peak , IOP mean , IO min , and IOP fluctuation were measured with both the mDTC and WDT. The paired sample t test, Spearman's correlation coefficient and Bland–Altman plots were used for statistical analysis. Results The mean age of the 42 patients consisting of 24 females and 18 males was 66.9 ± 6.8 years, and the mean central corneal thickness was 517.7 ± 29.1 µm. The mean values with the mDTC and WDT measurements were 15.05 ± 2.75 mmHg and 17.17 ± 3.25 mmHg ( p  ≤ 0.0001, r  = 0.884) for IOP mean , 16.76 ± 3.45 mmHg and 18.92 ± 3.94 mmHg ( p  ≤ 0.0001, r =0.787) for IOP peak , and 13.61 ± 2.56 mmHg and 15.11 ± 2.84 mmHg ( p  ≤ 0.0001, r =0.824) for IOP min , respectively, and a positive correlation was present between these values. Conclusion There was a positive correlation between the peak, minimum, and mean IOP values determined using the mDTC and WDT in treated XFG patients. WDT can be used as an alternative in the assessment of the IOP in these patients as a more practical method.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:0165-5701
1573-2630
DOI:10.1007/s10792-021-01847-5