Mobile phone applications for 3-dimensional scanning and digital anthropometry: a precision comparison with traditional scanners

Background The precision of digital anthropometry through 3-dimensional (3D) scanning has been established for relatively large, expensive, non-portable systems. The comparative performance of modern mobile applications is unclear. Subjects/methods Forty-six adults (age: 23.3 ± 5.3 y; BMI: 24.4 ± 4....

Full description

Saved in:
Bibliographic Details
Published inEuropean journal of clinical nutrition Vol. 78; no. 6; pp. 509 - 514
Main Authors Tinsley, Grant M., Rodriguez, Christian, Siedler, Madelin R., Tinoco, Ethan, White, Sarah J., LaValle, Christian, Brojanac, Alexandra, DeHaven, Brielle, Rasco, Jaylynn, Florez, Christine M., Graybeal, Austin J.
Format Journal Article
LanguageEnglish
Published London Nature Publishing Group UK 01.06.2024
Nature Publishing Group
Subjects
Online AccessGet full text

Cover

Loading…
More Information
Summary:Background The precision of digital anthropometry through 3-dimensional (3D) scanning has been established for relatively large, expensive, non-portable systems. The comparative performance of modern mobile applications is unclear. Subjects/methods Forty-six adults (age: 23.3 ± 5.3 y; BMI: 24.4 ± 4.1 kg/m 2 ) were assessed in duplicate using: (1) a mobile phone application capturing two individual 2D images, (2) a mobile phone application capturing serial images collected during a subject’s complete rotation, (3) a traditional scanner with a time of flight infrared sensor collecting visual data from a subject being rotated on a mechanical turntable, and (4) a commercial measuring booth with structured light technology using 20 infrared depth sensors positioned in the booth. The absolute and relative technical error of measurement (TEM) and intraclass correlation coefficient (ICC) for each method were established. Results Averaged across circumferences, the absolute TEM, relative TEM, and ICC were (1) 0.9 cm, 1.5%, and 0.975; (2) 0.5 cm, 0.9%, and 0.986; (3) 0.8 cm, 1.5%, and 0.974; and (4) 0.6 cm, 1.1%, and 0.985. For total body volume, these values were (1) 2.2 L, 3.0%, and 0.978; (2) 0.8 L, 1.1%, and 0.997; (3) 0.7 L, 0.9%, and 0.998; and (4) 0.8 L, 1.1%, and 0.996, with segmental volumes demonstrating higher relative errors. Conclusion A 3D scanning mobile phone application involving full rotation of subjects in front of a smartphone camera exhibited similar reliability to larger, less portable, more expensive 3D scanners. In contrast, larger errors were observed for a mobile scanning application utilizing two 2D images, although the technical errors were acceptable for some applications.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0954-3007
1476-5640
1476-5640
DOI:10.1038/s41430-024-01424-w