Preliminary Results With a Novel Expanded Polytetrafluoroethylene-based Pulmonary Valved Conduit

A novel polymeric pulmonary valved conduit, resistant to calcification and structural valve deterioration, may provide a more durable therapy option for the pediatric population by preventing loss of right ventricular function and increasing freedom from valve-related reintervention and mortality. T...

Full description

Saved in:
Bibliographic Details
Published inThe Annals of thoracic surgery Vol. 114; no. 6; pp. 2314 - 2321
Main Authors Baird, Christopher W., Chávez, Mariana, Backer, Carl L., Galantowicz, Mark E., Del Nido, Pedro J.
Format Journal Article
LanguageEnglish
Published Netherlands Elsevier Inc 01.12.2022
Online AccessGet full text

Cover

Loading…
More Information
Summary:A novel polymeric pulmonary valved conduit, resistant to calcification and structural valve deterioration, may provide a more durable therapy option for the pediatric population by preventing loss of right ventricular function and increasing freedom from valve-related reintervention and mortality. This was a prospective, multicenter, single-arm study evaluating safety and performance of an investigational novel expanded polytetrafluoroethylene–based valve. Patients met study inclusion/exclusion criteria, had a signed informed consent, had pre- and postoperative evaluation via transthoracic echocardiography, and 6-month cardiac magnetic resonance imaging. Seventeen patients were enrolled from 3 sites. Median age was 12 years (range, 6-17 years) with 52.9% male. Body surface area ranged from 0.82 to 1.57 m2. There has been no mortality and 100% freedom from device related reinterventions. Baseline compared with 6-month cardiac magnetic resonance imaging (in 11 of 16 patients with available data) suggests favorable right ventricular remodeling (right ventricular end-diastolic volume, 123 ± 37 to 94 ± 25 mL/m2) with no significant change in ejection fraction. Through current follow-up, no patient has a right ventricular outflow tract gradient >20 mm Hg (mean, 11.2 ± 4.3 mm Hg). No evidence of worsening valvular insufficiency was observed throughout postoperative serial transthoracic echocardiogram evaluations. No pulmonary regurgitation above baseline (≤ mild) was observed. No patient developed endocarditis. No thrombus or calcification was identified. This preliminary evaluation of a novel expanded polytetrafluoroethylene–based valved conduit suggests promising valve function with no thromboembolic or infectious complications, no valve related reinterventions, no valve-related adverse events or unexpected findings, improved right ventricular volumes, and encouraging hemodynamic performance through current follow-up.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0003-4975
1552-6259
DOI:10.1016/j.athoracsur.2021.10.033